Ábalos Manuela, Cojocariu Cristian I, Silcock Paul, Roberts Dominic, Pemberthy Diana M, Sauló Jordi, Abad Esteban
Spanish Council for Scientific Research (CSIC), Institute of Environmental Assessment and Water Research, C/ Jordi Girona 18-26, 08034, Barcelona, Spain.
Thermo Fisher Scientific, Tudor Road, Manor Park, Runcorn, Cheshire, WA7 1TA, UK.
Anal Bioanal Chem. 2016 May;408(13):3511-25. doi: 10.1007/s00216-016-9428-9. Epub 2016 Feb 27.
Until recently, European Union (EU) legislation required the use of high-resolution gas chromatography coupled to high-resolution mass spectrometry (HRGC-HRMS) based on magnetic sector analyzers as a standard approach for confirmatory analysis of dioxins (PCDDs) and furans (PCDFs) in feed and food. However, recent technological advances in MS instruments enabled other alternative analytical techniques to meet the same analytical criteria as those requested for HRGC-HRMS. In this sense, triple quadrupoles (GC-MS/MS) can be a realistic alternative for the analysis of dioxins. In this work, the performance of GC-MS/MS technology was evaluated against the criteria demanded by the EU for confirmatory analysis of dioxins and PCBs in food and feed. Thus, the study comprises a number of parameters including chromatographic separation, limit of quantification, linearity, repeatability, and ion ratio precision. Analyses of solvent standards as well as sample extracts (inter-calibration extracts and certified reference materials) were also considered within the scope of this study. Additionally, direct comparisons of the results obtained by GC-MS/MS with those from GC-HRMS were made. The results of this work suggested that GC-MS/MS was highly sensitive and selective for confirmatory analysis of PCDD/Fs and related compounds in food and feed samples and meets all the criteria requested by the European Commission.
直到最近,欧盟(EU)的法规还要求使用基于磁扇区分析仪的高分辨率气相色谱与高分辨率质谱联用(HRGC-HRMS)作为饲料和食品中二噁英(PCDDs)和呋喃(PCDFs)确证分析的标准方法。然而,质谱仪器最近的技术进步使其他替代分析技术能够满足与HRGC-HRMS相同的分析标准。从这个意义上说,三重四极杆(GC-MS/MS)可以成为二噁英分析的一种切实可行的替代方法。在这项工作中,根据欧盟对食品和饲料中二噁英和多氯联苯确证分析的要求,对GC-MS/MS技术的性能进行了评估。因此,该研究包括许多参数,包括色谱分离、定量限、线性、重复性和离子比精密度。本研究范围内还考虑了溶剂标准品以及样品提取物(内部校准提取物和有证标准物质)的分析。此外,还对GC-MS/MS与GC-HRMS所得结果进行了直接比较。这项工作的结果表明,GC-MS/MS对食品和饲料样品中PCDD/Fs及相关化合物的确证分析具有高灵敏度和选择性,并且符合欧盟委员会要求的所有标准。