AIM

The aim of the study is to analyze the effect of different materials and techniques in current use on peripheral shaping of complete denture impression.

METHODS

The present study was conducted to compare and evaluate the maxillary border morphology produced using tissue conditioner as control and low fusing impression compound, Polyether, Pattern resin and periphery wax as border molding materials. The study was carried out on 15 denture wearer patients with well formed, rounded edentulous maxillary arch with adequate width and height. On each patient, border moldings were done, with tissue conditioner which was loaded on the borders of previous maxillary denture of the patient (control group), low fusing impression compound (Group 1), polyether (Group 2), Pattern resin (Group 3) and Peripheral wax (Group 4), respectively on special tray made for the patient. Sulcus width height and area was then measured for each group using stereomicroscope.

RESULTS AND CONCLUSIONS

Based on the study it is concluded that the polyether was the best material for border molding which will give most accurate borders to a denture.

摘要
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/78d1/4762307/0c693590bef5/JIPS-15-102-g001.jpg

相似文献

4
One-step border molding of complete denture impressions using a polyether impression material.
J Prosthet Dent. 1979 Mar;41(3):347-51. doi: 10.1016/0022-3913(79)90022-2.
9
Laboratory investigation of Accuracy of Impression Materials for Border Molding.
Folia Med (Plovdiv). 2019 Sep 30;61(3):435-443. doi: 10.3897/folmed.61.e39351.
10
An alternative impression technique for complete dentures.
J Prosthet Dent. 2014 Feb;111(2):166-8. doi: 10.1016/j.prosdent.2013.04.006. Epub 2013 Nov 25.

本文引用的文献

1
Single Stage Silicone Border Molded Closed Mouth Impression Technique-Part II.单阶段硅胶边缘成型闭口印模技术 - 第二部分。
J Indian Prosthodont Soc. 2011 Sep;11(3):183-8. doi: 10.1007/s13191-011-0098-1. Epub 2011 Sep 10.
2
Six fundamental rules for making full denture impressions.
J Prosthet Dent. 1951 Jan-Mar;1(1-2):135-44. doi: 10.1016/0022-3913(51)90087-x.
5
Displacement of border tissues during final impression procedures.
J Prosthet Dent. 1994 Feb;71(2):133-8. doi: 10.1016/0022-3913(94)90020-5.
7
An alternative approach to conventional border molding.
J Prosthet Dent. 1985 May;53(5):745-6. doi: 10.1016/0022-3913(85)90038-1.
8
One-step border molding.
J Prosthet Dent. 1985 Apr;53(4):598-9. doi: 10.1016/0022-3913(85)90661-4.
10
Border molding with composition heated in a microwave oven.
J Prosthet Dent. 1991 Feb;65(2):325. doi: 10.1016/0022-3913(91)90184-x.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验