• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Preliminary design of electrostatic sensors for MITICA beam line components.

作者信息

Spagnolo S, Spolaore M, Dalla Palma M, Pasqualotto R, Sartori E, Serianni G, Veltri P

机构信息

Consorzio RFX, Associazione EURATOM-ENEA sulla Fusione, 35127 Padova, Italy.

出版信息

Rev Sci Instrum. 2016 Feb;87(2):02B931. doi: 10.1063/1.4935612.

DOI:10.1063/1.4935612
PMID:26932103
Abstract

Megavolt ITER Injector and Concept Advancement, the full-scale prototype of ITER neutral beam injector, is under construction in Italy. The device will generate deuterium negative ions, then accelerated and neutralized. The emerging beam, after removal of residual ions, will be dumped onto a calorimeter. The presence of plasma and its parameters will be monitored in the components of the beam-line, by means of specific electrostatic probes. Double probes, with the possibility to be configured as Langmuir probes and provide local ion density and electron temperature measurements, will be employed in the neutralizer and in the residual ion dump. Biased electrodes collecting secondary emission electrons will be installed in the calorimeter with the aim to provide a horizontal profile of the beam.

摘要

相似文献

1
Preliminary design of electrostatic sensors for MITICA beam line components.
Rev Sci Instrum. 2016 Feb;87(2):02B931. doi: 10.1063/1.4935612.
2
In-vacuum sensors for the beamline components of the ITER neutral beam test facility.
Rev Sci Instrum. 2016 Nov;87(11):11D417. doi: 10.1063/1.4959954.
3
Final design of the beam source for the MITICA injector.
Rev Sci Instrum. 2016 Feb;87(2):02B309. doi: 10.1063/1.4932615.
4
Diagnostics of the ITER neutral beam test facility.
Rev Sci Instrum. 2012 Feb;83(2):02B103. doi: 10.1063/1.3662017.
5
Concepts for the magnetic design of the MITICA neutral beam test facility ion accelerator.
Rev Sci Instrum. 2012 Feb;83(2):02B107. doi: 10.1063/1.3669801.
6
Transmission of electrons inside the cryogenic pumps of ITER injector.
Rev Sci Instrum. 2016 Feb;87(2):02B313. doi: 10.1063/1.4933187.
7
Modeling and simulation of a beam emission spectroscopy diagnostic for the ITER prototype neutral beam injector.
Rev Sci Instrum. 2014 Nov;85(11):11E430. doi: 10.1063/1.4891973.
8
Neutron measurements at the ELISE neutral beam test facility and implications for neutron based diagnostics at SPIDER.在ELISE中性束测试设施进行的中子测量及其对SPIDER中基于中子的诊断的影响。
Rev Sci Instrum. 2018 Oct;89(10):10I139. doi: 10.1063/1.5036823.
9
Development of a negative ion-based neutral beam injector in Novosibirsk.新西伯利亚负离子基中性束注入器的研制。
Rev Sci Instrum. 2014 Feb;85(2):02B102. doi: 10.1063/1.4826326.
10
Steady state thermal-hydraulic analyses of the MITICA cooling circuits.麻省理工学院国际合作聚变研究装置冷却回路的稳态热工水力分析
Rev Sci Instrum. 2016 Feb;87(2):02B323. doi: 10.1063/1.4936919.