Suppr超能文献

用于检测活细胞释放的基质金属蛋白酶2的简单灵敏的基于肽的电化学发光生物传感器。

Simple and sensitive electrogenerated chemiluminescence peptide-based biosensor for detection of matrix metalloproteinase 2 released from living cells.

作者信息

Dang Qian, Gao Hongfang, Li Zhejian, Qi Honglan, Gao Qiang, Zhang Chengxiao

机构信息

Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062, China.

College of Chemical Engineering and Modern Materials, Shangluo University, Shangluo, 726000, China.

出版信息

Anal Bioanal Chem. 2016 Oct;408(25):7067-75. doi: 10.1007/s00216-016-9360-z. Epub 2016 Mar 3.

Abstract

A simple and sensitive electrogenerated chemiluminescence biosensor was developed to monitor matrix metalloproteinase 2 (MMP-2) by employing a specific peptide (CGPLGVRGK) as a molecular recognition substrate. Bis(2,2'-bipyridine)-4'-methyl-4-carboxybipyridine-ruthenium N-succinimidyl ester-bis(hexafluorophosphate) (Ru(bpy)2(mcbpy-O-Su-ester)(PF6)2 (Ru1) was used as ECL-emitting species and covalently labeled onto the peptide through NH2-containing lysine on the peptide via acylation reaction to form Ru1-peptide as an ECL probe. An ECL peptide-based biosensor was fabricated by self-assembling the ECL probe onto the surface of gold electrode. MMP-2 can specifically cleave the Ru1-peptide on the electrode surface, which led the partly Ru1-peptide to leave the electrode surface and resulted in the decrease of the ECL intensity obtained from the resulted electrode in 0.1 M phosphate-buffered saline (pH 7.4) containing tri-n-propylamine. The decreased ECL intensity was piecewise linear to the concentration of MMP-2 in the range from 1 to 500 ng/mL. Moreover, the ECL biosensor is successfully applied to detection of MMP-2 secreted by living cell, such as HeLa cells. Additionally, the biosensor was also applied to the evaluation of matrix metalloproteinase inhibitors. The strategy presented here is promising for other disease-related matrix metalloproteinase assay and matrix metalloproteinase inhibitor profiling with sensitivity and simplicity. Graphical Abstract Detection of MMP-2 released from living cells by ECL peptide-based biosensor.

摘要

开发了一种简单灵敏的电化学发光生物传感器,通过使用特定肽(CGPLGVRGK)作为分子识别底物来监测基质金属蛋白酶2(MMP-2)。双(2,2'-联吡啶)-4'-甲基-4-羧基联吡啶钌N-琥珀酰亚胺酯-双(六氟磷酸盐)(Ru(bpy)2(mcbpy-O-Su-ester)(PF6)2 (Ru1)用作电化学发光发光物质,并通过肽上含NH2的赖氨酸经酰化反应共价标记到肽上,形成Ru1-肽作为电化学发光探针。通过将电化学发光探针自组装到金电极表面制备了基于电化学发光肽的生物传感器。MMP-2可以特异性切割电极表面的Ru1-肽,导致部分Ru1-肽离开电极表面,从而使所得电极在含有三正丙胺的0.1 M磷酸盐缓冲盐水(pH 7.4)中获得的电化学发光强度降低。降低的电化学发光强度与MMP-2浓度在1至500 ng/mL范围内呈分段线性关系。此外,该电化学发光生物传感器成功应用于检测活细胞(如HeLa细胞)分泌的MMP-2。此外,该生物传感器还应用于基质金属蛋白酶抑制剂的评估。这里提出的策略对于其他与疾病相关的基质金属蛋白酶测定和基质金属蛋白酶抑制剂分析具有灵敏度高和操作简单的前景。图形摘要:基于电化学发光肽的生物传感器检测活细胞释放的MMP-2。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验