Dixit R B, Neema M M
Department of Anesthesiology, R.D. Gardi Medical College, Ujjain, Madhya Pradesh, India.
Saudi J Anaesth. 2016 Jan-Mar;10(1):29-32. doi: 10.4103/1658-354X.169471.
Head down tilt is given to patients after sub arachnoid block for adjustment of height of block. However, the amount of tilt given is subjective and cannot be documented.
We used an android application named "clinometer" to measure exact degree of tilt given by anesthesiologists as their routine practice.
This observational study, at a medical college hospital, was done in 130 patients given sub arachnoid block for lower abdominal surgeries.
We observed and documented vital data of patients and measured tilt given by application "clinometer."
We observed that the application was easy to use and measured tilt each time. The result obtained can be documented, digitally saved and transferred. In 130 patients studied, we observed incidence of degree of tilt as follows: 6-8° tilt in 38 patients (29.23%), 8-10 in 36 patients (27.69%), 10-12 in 30 patients (23.08%), 12-14 in 12 patients (9.23%) and 14-16° tilt in 14 patients (10.77%). Use of application was received with enthusiasm by practicing anesthesiologists. Various possible uses of this application are discussed.
蛛网膜下腔阻滞术后给患者采取头低位以调整阻滞平面高度。然而,所采用的倾斜角度是主观的,无法记录。
我们使用一款名为“倾角仪”的安卓应用程序来测量麻醉医生在日常操作中给予的精确倾斜角度。
这项观察性研究在一所医学院附属医院进行,纳入了130例接受蛛网膜下腔阻滞以进行下腹部手术的患者。
我们观察并记录患者的重要数据,并使用“倾角仪”应用程序测量倾斜角度。
我们观察到该应用程序易于使用,每次都能测量倾斜角度。所获得的结果可以记录、数字保存并传输。在研究的130例患者中,我们观察到的倾斜角度发生率如下:38例患者(29.23%)为6 - 8°倾斜,36例患者(27.69%)为8 - 10°,30例患者(23.08%)为10 - 12°,12例患者(9.23%)为12 - 14°,14例患者(10.77%)为14 - 16°。执业麻醉医生对该应用程序的使用表现出热情。本文还讨论了该应用程序的各种可能用途。