Murphy Michael, Austin Conal, Bapat Vinayak, Morgan Gareth J
Department of Congenital Cardiology, Guys and St Thomas' NHS Foundation Trust, London, UK.
Department of Congenital Cardiology, Guys and St Thomas' NHS Foundation Trust, London, UK
Eur J Cardiothorac Surg. 2016 Sep;50(3):577-9. doi: 10.1093/ejcts/ezw076. Epub 2016 Mar 18.
An 11-year old boy, with complex left ventricular morphology in the setting of repaired double outlet right ventricle developed progressive mitral regurgitation leading to a repair which failed, necessitating replacement of the valve with a 21 mm St. Jude mechanical prosthesis. He represented 3 weeks later in extremis with signs of severe mitral stenosis. The valve was replaced via a hybrid technique with a 26 mm Edwards Sapien 3 valve mounted on a MEMO 3D annuloplasty ring. One year later, the valve is functioning well with no regurgitation or evidence of an inflow gradient.