Godinho Glaydson Gomes, França Flavio Oliveira, Alves Freitas José Marcio, Aguiar Paulo Nascimento, de Carvalho Leite Marcelo
Shoulder Group, Hospital Ortopédico and Hospital Belo Horizonte.
Shoulder Group, Hospital Ortopédico and Hospital da Polícia Militar de Minas Gerais.
Rev Bras Ortop. 2015 Nov 16;44(2):143-7. doi: 10.1016/S2255-4971(15)30061-6. eCollection 2009 Jan.
To identify the complications concerning the use of metal anchors in shoulder arthroscopic procedures.
28 shoulders of 28 patients (23 male and 5 female) have been re-operated in the period between December 1997 and August 2007, at Hospital Ortopédico, Belo Horizonte Hospital and Military Police Hospital in Belo Horizonte, MG, as a result of complications such as loose anchors and prominent anchors. The primary surgeries intended to treat 20 anterior traumatic instabilities (71.5%), one posterior instability (3.5%), one slap injury (3.5%), six procedures for treating injuries on the rotator cuff (21.5%). We used the X-ray classification suggested by Samilson and Prieto and Outerbridge arthroscopic classification for assessing patients' degree of arthrosis. All patients were evaluated by the UCLA (University of California at Los Angeles) index criteria.
In all patients, arthroscopic reviews were made. In two cases, after anchors removal, clinical signs of instability were seen, leading to the decision of providing open stabilization by Latarjet-Patte technique.
the complications with metallic-suture anchors result from inappropriate surgical techniques applied in arthroscopy.
确定在肩关节镜手术中使用金属锚钉的并发症。
1997年12月至2007年8月期间,在米纳斯吉拉斯州贝洛奥里藏特市的骨科医院、贝洛奥里藏特医院和军事警察医院,对28例患者(23例男性和5例女性)的28个肩部进行了再次手术,原因是出现了锚钉松动和锚钉突出等并发症。初次手术旨在治疗20例前侧创伤性不稳定(71.5%)、1例后侧不稳定(3.5%)、1例SLAP损伤(3.5%)、6例肩袖损伤治疗手术(21.5%)。我们采用Samilson和Prieto建议的X线分类以及Outerbridge关节镜分类来评估患者的关节病程度。所有患者均按照加州大学洛杉矶分校(UCLA)指数标准进行评估。
对所有患者进行了关节镜检查。在2例患者中,取出锚钉后出现了不稳定的临床体征,因此决定采用Latarjet - Patte技术进行切开复位内固定。
金属缝线锚钉的并发症是由于关节镜手术中应用了不恰当的手术技术所致。