Percope Andrade Marco Antônio, Rodrigues André Soares, Mendonça Celso Junio, Santos Portela Luiz Gustavo
Head of the Orthopedics and Traumatology Service of Hospital das Clínicas, Federal University of Minas Gerais (UFMG). Adjunct Professor in the School of Medicine, UFMG.
Orthopedist and Specialist in Hip Surgery. Member of the Clinical Staff of Risoleta Tolentino Neves University Hospital, UFMG.
Rev Bras Ortop. 2015 Nov 16;45(1):84-8. doi: 10.1016/S2255-4971(15)30222-6. eCollection 2010 Jan.
To determine, by means of comparative biomechanical tests, whether greater compressive load resistance and flexion is presented by 95° angled blade plates or by dynamic condylar screws (DCS), and to correlate the failure type presented during the tests with each type of plate.
Sixty-five porcine femurs were subjected to 1 cm medial wedge osteotomy, in the metaphysis, to simulate an unstable supracondylar femoral fracture. Osteosynthesis was performed on these pieces: 35 were fixed using 95° lateral blade plates and 30 with DCS plates. Another variable studied was the failure type presented in each group, in an attempt to correlate this with the type of plate.
There were no statistically significant differences in biomechanical resistance between the two types of plates, or between the failure type and the plate type used for the osteosynthesis.
The two types of plate behaved in a similar fashion. However, the angled blade plate proved to be superior to the DCS in the flexion test. No statistical difference in failure type or type of plate used was observed.
通过比较生物力学测试,确定95°角钢板或动力髁螺钉(DCS)是否具有更大的抗压负荷能力和屈曲能力,并将测试过程中出现的失效类型与每种钢板类型相关联。
对65根猪股骨进行干骺端1cm内侧楔形截骨术,以模拟不稳定的股骨髁上骨折。对这些骨块进行骨固定:35根使用95°外侧角钢板固定,30根使用DCS钢板固定。另一个研究变量是每组中出现的失效类型,试图将其与钢板类型相关联。
两种钢板在生物力学抗性方面,以及失效类型与用于骨固定的钢板类型之间,均无统计学上的显著差异。
两种钢板表现相似。然而,在屈曲测试中,角钢板被证明优于DCS。未观察到失效类型或所用钢板类型的统计学差异。