Lee Kanghaeng, Park Hyung Sub, Lee Taeseung
Division of Vascular and Transplantation Surgery, Department of Surgery, Seoul National University Bundang Hospital, Seongnam, Korea.
Vasc Specialist Int. 2016 Mar;32(1):22-5. doi: 10.5758/vsi.2016.32.1.22. Epub 2016 Mar 31.
Coil migration during endovascular procedures is not an unusual complication, but there is no standard management strategy for bailout. Here, we describe a technique for removal of a migrated coil using a snare. During embolization of type II endoleak from the inferior mesenteric artery in a post-endovascular aneurysm repair patient, the coil migrated to the sigmoidal artery causing an occlusion. We used a microsnare loop and successfully retrieved the migrated coil. This is the first case in Korea that uses a loop snare for the removal of a migrated coil during visceral endovascular treatment to our knowledge. This technique of using a microsnare for removal of displaced coils can be a good resort in selected cases.
血管内介入手术期间弹簧圈移位并非罕见的并发症,但目前尚无标准的补救管理策略。在此,我们描述一种使用圈套器取出移位弹簧圈的技术。在一名血管内动脉瘤修复术后患者的肠系膜下动脉II型内漏栓塞过程中,弹簧圈移位至乙状结肠动脉导致闭塞。我们使用微型圈套器环成功取出了移位的弹簧圈。据我们所知,这是韩国首例在内脏血管内治疗期间使用圈套器环取出移位弹簧圈的病例。在特定病例中,这种使用微型圈套器取出移位弹簧圈的技术可能是一种很好的解决办法。