Abstract

The changes in the contractile properties induced by a 30-Hz phasic stimulation paradigm were measured and compared with the changes induced by a 10-Hz continuous stimulation paradigm. The study was performed on the tibialis anterior muscles of cats with one paradigm applied to one hindlimb muscle and the other to the contralateral limb. Both hindlimb muscles received the same number of stimuli in a day, making the average stimulation frequency 10 Hz. Two periods of daily stimulation were studied, 8 and 24 h/day. Muscles stimulated at 30 Hz produced greater overall tetanic tension and, during a prolonged stimulation test, exerted a greater mean tension than muscles stimulated at 10 Hz (50 and 32% increase for animals stimulated for 8 and 24 h/day, respectively). Muscle mass was least reduced and fewer pathological abnormalities were observed in the muscles stimulated at 30 Hz. There were no apparent differences in the histochemistry or biochemistry between muscles stimulated at 10 and 30 Hz, which could account for these differences in muscle properties. These results indicate the 30-Hz paradigm may be better suited than 10 Hz continuous stimulation for applications requiring sustained muscle tension such as correction of scoliosis or muscle conditioning for motor prostheses.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验