Suppr超能文献

闭塞性透析通路的Aspirex血栓切除术:一项回顾性研究。

Aspirex Thrombectomy in Occluded Dialysis Access: A Retrospective Study.

作者信息

Dyer Jules, Rosa Joao, Chachlani Menka, Nicholas Johann

机构信息

Department of Radiology, New Cross Hospital, Wolverhampton, West Midlands, WV10 0QP, UK.

ST1 Radiology, University Hospitals Bristol NHS Foundation Trust, Bristol, UK.

出版信息

Cardiovasc Intervent Radiol. 2016 Oct;39(10):1484-90. doi: 10.1007/s00270-016-1351-0. Epub 2016 Apr 19.

Abstract

PURPOSE

This study is the first to present the outcomes of the Straub Aspirex device for the salvage of occluded renal dialysis access fistulae.

MATERIALS AND METHODS

This is a retrospective study, using data from the Renal Unit and Radiology Department database. It included all the patients between 2010 and 2014 who underwent percutaneous mechanical thrombectomy (PMT) treated by JD. Aspirex is an over-the-wire, 6-10 French catheter within which is a rapidly rotating helix which draws thrombus into a window near the tip which it then macerates and removes. Access survival was assessed using the Kaplan-Meier method, and multi-variant analysis was performed using the Cox proportional hazards model. Significance was considered if p < 0.05.

RESULTS

A total of 27 procedures were performed for 19 patients. 13 had autologous arterio-venous fistulae, and 14 had synthetic (PTFE) arterio-venous grafts. 15 were males, 4 females. 100 % of the patients successfully had a channel of thrombus removed. This resulted in an 81.5 % initial clinical success, with primary patency rates of 53.6, 44.3 and 33 % by days 30, 90 and 480, respectively, without significant difference of any analysed covariates. No major complication (pulmonary embolus, paradoxical cerebral infarction, limb ischaemia or significant haemorrhage) occurred.

CONCLUSION

Aspirex has rates of patency and complication similar to other PMT devices. No covariant studied affected outcome.

摘要

目的

本研究首次展示了使用Straub Aspirex装置挽救闭塞性肾透析通路瘘管的结果。

材料与方法

这是一项回顾性研究,使用了肾脏科和放射科数据库中的数据。研究纳入了2010年至2014年间所有接受经皮机械血栓切除术(PMT)且由JD治疗的患者。Aspirex是一种通过导丝操作的6-10法式导管,内部有一个快速旋转的螺旋,可将血栓吸入靠近尖端的窗口,然后将其粉碎并清除。使用Kaplan-Meier方法评估通路生存率,并使用Cox比例风险模型进行多变量分析。如果p < 0.05,则认为具有统计学意义。

结果

共为19名患者进行了27次手术。13例为自体动静脉内瘘,14例为人工合成(聚四氟乙烯)动静脉移植物。男性15例,女性4例。100%的患者成功清除了血栓通道。这导致初始临床成功率为81.5%,在第30天、90天和480天时的初次通畅率分别为53.6%、44.3%和33%,各分析协变量之间无显著差异。未发生重大并发症(肺栓塞、反常脑梗死、肢体缺血或严重出血)。

结论

Aspirex的通畅率和并发症发生率与其他PMT装置相似。所研究的协变量均未影响结果。