Suppr超能文献

前瞻性心电图门控高螺距双源心脏CT血管造影术在先天性心血管异常诊断中的应用:儿科人群的辐射剂量与诊断效能

Prospective ECG-gated high-pitch dual-source cardiac CT angiography in the diagnosis of congenital cardiovascular abnormalities: Radiation dose and diagnostic efficacy in a pediatric population.

作者信息

Koplay M, Kizilca O, Cimen D, Sivri M, Erdogan H, Guvenc O, Oc M, Oran B

机构信息

Department of Radiology, Medical Faculty, Selcuk University, Konya, Turkey.

Department of Radiology, Horasan Government Hospital, Erzurum, Turkey.

出版信息

Diagn Interv Imaging. 2016 Nov;97(11):1141-1150. doi: 10.1016/j.diii.2016.03.014. Epub 2016 May 4.

Abstract

PURPOSE

The goal of this study was to investigate the radiation dose and diagnostic efficacy of cardiac computed tomography angiography (CCTA) using prospective ECG-gated high-pitch dual-source computed tomography (DSCT) in the diagnosis of congenital cardiovascular abnormalities in pediatric population.

MATERIALS AND METHODS

One hundred five pediatric patients who were clinically diagnosed with congenital heart disease with suspected extracardiac vascular abnormalities were included in the study. All CCTAs were performed on a 128×2-section DSCT scanner. CCTA findings were compared with surgical and/or conventional cardiac angiography findings. Dose-length product (DLP) and effective doses (ED) were calculated for each patient. Patients were divided into 4 groups by age, and ED and DLP values were compared among groups. The image quality was evaluated using a five-point scale.

RESULTS

CCTA showed 173 abnormalities in 105 patients. There were 2 patients with false positive and 3 with false negative findings. The sensitivity and specificity of CCTA were 98.3% and 99.9%, respectively. The positive predictive value and negative predictive value of CCT were 98.9% and 99.9%, respectively. The average DLP and ED values were 15.6±9.6 (SD) mGy.cm and 0.34±0.10 (SD) mSv, respectively. The mean image quality score was 4.8±0.5 (SD) in all patients. The inter-observer agreement for the image quality scores was good (κ=0.80).

CONCLUSION

CCTA is an excellent imaging modality for evaluation of cardiovascular abnormalities and provides excellent image quality with very low radiation exposure when low-dose prospective ECG-triggered high-pitch DSCT is used.

摘要

目的

本研究的目的是探讨采用前瞻性心电图门控高螺距双源计算机断层扫描(DSCT)的心脏计算机断层血管造影(CCTA)在诊断儿童先天性心血管异常中的辐射剂量和诊断效能。

材料与方法

本研究纳入105例临床诊断为先天性心脏病且怀疑有心外血管异常的儿科患者。所有CCTA检查均在128×2层DSCT扫描仪上进行。将CCTA检查结果与手术和/或传统心脏血管造影结果进行比较。计算每位患者的剂量长度乘积(DLP)和有效剂量(ED)。根据年龄将患者分为4组,并比较各组的ED和DLP值。采用五分制对图像质量进行评估。

结果

CCTA在105例患者中显示出173处异常。有2例假阳性和3例假阴性结果。CCTA的敏感性和特异性分别为98.3%和99.9%。CCT的阳性预测值和阴性预测值分别为98.9%和99.9%。平均DLP和ED值分别为15.6±9.6(标准差)mGy·cm和0.34±0.10(标准差)mSv。所有患者的平均图像质量评分为4.8±0.5(标准差)。观察者间图像质量评分的一致性良好(κ=0.80)。

结论

当使用低剂量前瞻性心电图触发高螺距DSCT时,CCTA是评估心血管异常的一种优秀成像方式,能提供高质量图像且辐射暴露极低。