Savini Giacomo, Hoffer Kenneth J, Schiano-Lomoriello Domenico, Ducoli Pietro
J Refract Surg. 2016 May 1;32(5):332-6. doi: 10.3928/1081597X-20160225-03.
To investigate whether the Estimated Pre-Refractive SimK accurately predicts the preoperative corneal power (K) in eyes with previous myopic femtosecond laser-assisted LASIK (FS-LASIK) and whether a better prediction can be developed.
Preoperatively and 3 months after FS-LASIK, patients underwent anterior segment imaging with the Pentacam HR rotating Scheimpflug camera (Oculus Optikgeräte, Wetzlar, Germany). Posterior and anterior corneal curvature and power and asphericity (Q-value at 8 mm) were recorded. Multiple linear regression was used to assess the relationship among variables.
One hundred four eyes of 104 patients were enrolled. The Estimated Pre-Refractive SimK (43.19 ± 1.63 diopters [D]) was lower (P = .0014) than the mean preoperative K (43.44 ± 1.49 D). The difference was within ±0.50 and ±1.00 D in 53.8% and 86.5% of eyes, respectively. Multiple linear regression detected a statistically significant relationship (r(2) = 0.8497, P < .0001) among the investigated parameters: preoperative anterior corneal radius = 1.156 + 1.012 * postoperative posterior corneal radius - 0.3800 * postoperative Q-value. When this equation was used to predict the preoperative K, the difference between the actual preoperative K and the predicted value (43.41 ± 1.38 D) was not statistically significant. The rate of eyes with a difference between the predicted and actual preoperative K within ±0.50 and ±1.00 D increased to 61.5% and 93.3%, respectively.
The corneal power before FS-LASIK can be accurately predicted from the postoperative corneal measurements of a rotating Scheimpflug camera. The multiple regression formula described may be more accurate than the Estimated Pre-Refractive SimK available on the Pentacam. [J Refract Surg. 2016;32(5):332-336.].
研究预估屈光术前SimK是否能准确预测既往接受过近视飞秒激光原位角膜磨镶术(FS-LASIK)的眼睛的术前角膜屈光度(K值),以及是否能建立更好的预测方法。
在FS-LASIK术前及术后3个月,患者使用Pentacam HR旋转式Scheimpflug相机(德国韦茨拉尔的Oculus Optikgeräte公司)进行眼前节成像。记录角膜前后表面曲率、屈光度及非球面性(8mm处的Q值)。采用多元线性回归分析评估各变量之间的关系。
纳入104例患者的104只眼。预估屈光术前SimK(43.19±1.63屈光度[D])低于术前平均K值(43.44±1.49D)(P = 0.0014)。分别有53.8%和86.5%的眼睛差异在±0.50D和±1.00D以内。多元线性回归分析显示,所研究参数之间存在显著统计学关系(r² = 0.8497,P < 0.0001):术前角膜前表面半径 = 1.156 + 1.012×术后角膜后表面半径 - 0.3800×术后Q值。当用该公式预测术前K值时,实际术前K值与预测值(43.41±1.38D)之间的差异无统计学意义。预测值与实际术前K值差异在±0.50D和±1.00D以内的眼睛比例分别增至61.5%和93.3%。
通过旋转式Scheimpflug相机的术后角膜测量结果可准确预测FS-LASIK术前的角膜屈光度。所描述的多元回归公式可能比Pentacam上现有的预估屈光术前SimK更准确。[《屈光手术杂志》。2016;32(5):332 - 336。]