Suppr超能文献

Gradient-echo imaging of hemorrhage at 1.5 Tesla.

作者信息

Unger E C, Cohen M S, Brown T R

机构信息

Department of Radiology, Fox Chase Cancer Center, Philadelphia, PA.

出版信息

Magn Reson Imaging. 1989 Mar-Apr;7(2):163-72. doi: 10.1016/0730-725x(89)90700-5.

Abstract

We report in vitro and in vivo MR studies of hemorrhage using the gradient-echo pulse sequence, FISP (steady state free precession) and FLASH (spoiling of transverse magnetization) at 1.5 Tesla. Phantoms containing methemoglobin, ferromagnetic particles, human serum and blood clot were scanned using both spin-echo and gradient-echo techniques. FLASH signal intensities were more sensitive to methemoglobin concentration than high T1-weighted spin-echo images. FISP showed little change in signal intensity with varying concentrations of methemoglobin and a contrast relationship similar to T2-weighted spin-echo techniques. FISP and FLASH showed intensity changes at lower concentrations of ferromagnetic material than T2-weighted spin-echo sequences. In vitro blood clot was less intense when observed by FISP and FLASH sequences than on the T2-weighted spin-echo sequences. Maximum contrast between clot and other blood components occurred at a flip angle of 45 degrees for FLASH and 60 degrees for FISP. FISP and FLASH scans of patients with hemorrhage demonstrated a marked decrease in signal intensity in the region of blood clot. This decrease was more pronounced with the gradient-echo sequences than with T2-weighted spin-echo images. We conclude that FLASH is useful for detecting methemoglobin and that both FISP and FLASH are useful for evaluating hemorrhage because of their sensitivity to methemoglobin.

摘要

相似文献

1
Gradient-echo imaging of hemorrhage at 1.5 Tesla.
Magn Reson Imaging. 1989 Mar-Apr;7(2):163-72. doi: 10.1016/0730-725x(89)90700-5.
4
A comparison of fast spin echo and gradient field echo sequences.
Magn Reson Imaging. 1988 Jul-Aug;6(4):373-89. doi: 10.1016/0730-725x(88)90474-2.
10

引用本文的文献

4
Essentials of trauma: head and spine.创伤要点:头部与脊柱
Pediatr Radiol. 2009 Jun;39 Suppl 3:391-405. doi: 10.1007/s00247-009-1203-z.
6
Is haemosiderin visible indefinitely on gradient-echo MRI following traumatic intracerebral haemorrhage?
Neuroradiology. 2003 Dec;45(12):881-6. doi: 10.1007/s00234-003-1048-3. Epub 2003 Oct 25.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验