Suppr超能文献

在比较BOD POD和双能X线吸收法(DXA)后,百分位数和标准位置的相应变化。

Resulting Shifts in Percentile and Standard Placements after Comparison of the BOD POD and DXA.

作者信息

Heden Timothy, Shepard Steve, Smith John, Covington Kay, Lecheminant James

机构信息

Human Performance Laboratory, Kinesiology and Health Education Department, Southern Illinois University Edwardsville, Edwardsville, Illinois, USA.

Texas A&M University-Kingsville, System Center, San Antonio, Texas, USA.

出版信息

Int J Exerc Sci. 2008 Jul 15;1(3):113-124. doi: 10.70252/EIHL7353. eCollection 2008.

Abstract

The purpose of this study was to determine the validity of the BOD POD® when compared to the DXA and if placement on a percentile chart and standard table is affected by any differences between the two measures. A total of 244 (27.7 ± 10.8 yrs, 77.3 ± 16.1 kg, 171.4 ± 10.1 cm, 26.31 ± 5.42 BMI) males and females between the ages of 18 and 52 were recruited to participate in this study. The participant's body fat percentage (%BF) was tested in random order on the BOD POD® and DXA during a 30-minute session following manufacturer's guidelines and procedures. Dependent t-test indicated the %BF measured by the BOD POD® (23.4% ± 12.8) was significantly lower when compared to the DXA (29.5% ± 12.1), p = .001. The Pearson's Product moment correlation was 0.95 (p = .001), indicating a very strong relationship between the two instruments. Using estimates of %BF from the BOD POD® also resulted in more favorable shifts on a percentile chart and standard table. Since a high correlation was evident between the two, the BOD POD® can be used as an instrument to track %BF changes over time during a diet and/or exercise intervention. However, caution should be made when classifying %BF with percentile charts or standard tables using the BOD POD® %BF estimates.

摘要

本研究的目的是确定与双能X线吸收法(DXA)相比,BOD POD®的有效性,以及两种测量方法之间的差异是否会影响百分位图表和标准表上的定位。总共招募了244名年龄在18至52岁之间的男性和女性(年龄27.7±10.8岁,体重77.3±16.1千克,身高171.4±10.1厘米,体重指数26.31±5.42)参与本研究。按照制造商的指南和程序,在30分钟的时间段内,以随机顺序在BOD POD®和DXA上对参与者的体脂百分比(%BF)进行测试。配对t检验表明,与DXA测量的%BF(29.5%±12.1)相比,BOD POD®测量的%BF(23.4%±12.8)显著更低,p = 0.001。皮尔逊积矩相关性为0.95(p = 0.001),表明两种仪器之间存在非常强的关系。使用BOD POD®的%BF估计值在百分位图表和标准表上也产生了更有利的偏移。由于两者之间存在明显的高相关性,BOD POD®可作为一种工具,用于跟踪饮食和/或运动干预期间%BF随时间的变化。然而,在使用BOD POD®的%BF估计值通过百分位图表或标准表对%BF进行分类时应谨慎。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/af83/4739294/222213704b11/ijes_01_03_113f1.jpg

相似文献

1
Resulting Shifts in Percentile and Standard Placements after Comparison of the BOD POD and DXA.
Int J Exerc Sci. 2008 Jul 15;1(3):113-124. doi: 10.70252/EIHL7353. eCollection 2008.
3
Agreement Between 2 Segmental Bioimpedance Devices, BOD POD, and DXA in Obese Adults.
J Clin Densitom. 2020 Jan-Mar;23(1):138-148. doi: 10.1016/j.jocd.2019.04.005. Epub 2019 Apr 27.
4
Comparison of Body Composition Methods for Estimating Body Fat Percentage in Lower Limb Prosthesis Users.
Can Prosthet Orthot J. 2023 Nov 10;6(1):41605. doi: 10.33137/cpoj.v6i1.41605. eCollection 2023.
5
Reliability and intermethod agreement for body fat assessment among two field and two laboratory methods in adolescents.
Obesity (Silver Spring). 2012 Jan;20(1):221-8. doi: 10.1038/oby.2011.272. Epub 2011 Aug 25.
6
Measures of body fat in South Asian adults.
Nutr Diabetes. 2013 May 27;3(5):e69. doi: 10.1038/nutd.2013.10.
7
Body-composition assessment via air-displacement plethysmography in adults and children: a review.
Am J Clin Nutr. 2002 Mar;75(3):453-67. doi: 10.1093/ajcn/75.3.453.
10
Validation of air displacement plethysmography for assessing body composition.
Med Sci Sports Exerc. 2000 Jul;32(7):1339-44. doi: 10.1097/00005768-200007000-00023.

本文引用的文献

1
Reliability of air displacement plethysmography in a large, heterogeneous sample.
Med Sci Sports Exerc. 2006 Aug;38(8):1505-9. doi: 10.1249/01.mss.0000228950.60097.01.
4
Comparison of the Bod Pod and dual energy x-ray absorptiometry in men.
Physiol Meas. 2004 Jun;25(3):671-8. doi: 10.1088/0967-3334/25/3/007.
5
Comparison of Bod Pod and DXA in female collegiate athletes.
Med Sci Sports Exerc. 2004 Apr;36(4):731-5. doi: 10.1249/01.mss.0000121943.02489.2b.
7
Comparison of bone mineral density and body composition measurements in women obtained from two DXA instruments.
Mech Ageing Dev. 2003 Mar;124(3):317-21. doi: 10.1016/s0047-6374(02)00199-9.
9
Evaluation of the BOD POD for estimating percentage body fat in a heterogeneous group of adult humans.
Eur J Appl Physiol. 2001 Aug;85(3-4):326-32. doi: 10.1007/s004210100459.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验