[Research on On-Line Calibration Based Photoacoustic Spectrometry System for Monitoring the Concentration of CO2 in Atmosphere].

作者信息

Zhang Jian-feng, Pan Sun-qiang, Lin Xiao-lu, Hu Peng-bing, Chen Zhe-min

出版信息

Guang Pu Xue Yu Guang Pu Fen Xi. 2016 Jan;36(1):1-5.

PMID:27228729
Abstract

Resonate frequency and cell constant of photoacoustic spectrum system are usually calibrated by using standard gas in laboratory, whereas the resonate frequency and cell constant will be changed in-situ, leading to measurement accuracy errors, caused by uncertainties of standard gas, differences between standard and measured gas components and changes in environmental condition, such as temperature and humidity. As to overcome the above problems, we have proposed an on-line atmospheric oxygen-based calibration technology for photoacoustic spectrum system and used in measurement of concentration of carbon dioxide in atmosphere. As the concentration of atmospheric oxygen is kept as constant as 20.96%, the on-line calibration for the photoacoustic spectrum system can be realized by detecting the swept-frequency and peak signal at 763.73 nm. The cell of the PAS has a cavity with length of 100 mm and an inner diameter of 6 mm, and worked in a first longitudinal resonant mode. The influence of environmental temperature and humidity, gas components on the photoacoustic cell's performance has been theoretically analyzed, and meanwhile the resonant frequencies and cell constants were calibrated and acquired respectively using standard gas, indoor air and outdoor air. Compared with calibrated gas analyzer, concentration of carbon dioxide is more accurate by using the resonant frequency and cell constant calculated by oxygen in tested air, of which the relative error is less than 1%, much smaller than that calculated by the standard gas in laboratory. The innovation of this paper is that using atmospheric oxygen as photoacoustic spectrum system's calibration gas effectively reduces the error caused by using standard gas and environmental condition changes, and thus improves the on-line measuring accuracy and reliability of the photoacoustic spectrum system.

摘要

相似文献

1
[Research on On-Line Calibration Based Photoacoustic Spectrometry System for Monitoring the Concentration of CO2 in Atmosphere].
Guang Pu Xue Yu Guang Pu Fen Xi. 2016 Jan;36(1):1-5.
2
Calibration of Quartz-Enhanced Photoacoustic Sensors for Real-Life Adaptation.石英增强光声传感器的现场适应性校准。
Molecules. 2021 Jan 25;26(3):609. doi: 10.3390/molecules26030609.
3
[Development of a photoacoustic spectroscopy system for the measurement of absorption coefficient of atmospheric aerosols].[用于测量大气气溶胶吸收系数的光声光谱系统的研制]
Guang Pu Xue Yu Guang Pu Fen Xi. 2013 Jul;33(7):1729-33.
4
Photoacoustic detection of CO2 based on LABVIEW at 10.303 μm.基于LABVIEW在10.303μm波长处对二氧化碳进行光声检测。
Rev Sci Instrum. 2011 Apr;82(4):044904. doi: 10.1063/1.3584867.
5
Measurement of blood-oxygen saturation using a photoacoustic technique in the rabbit hypoxemia model.在兔低氧血症模型中使用光声技术测量血氧饱和度。
J Clin Monit Comput. 2019 Apr;33(2):269-279. doi: 10.1007/s10877-018-0166-8. Epub 2018 Jun 6.
6
Effect of variation in argon content of calibration gases on determination of atmospheric carbon dioxide.校准气体中氩含量变化对大气二氧化碳测定的影响。
Talanta. 2009 Dec 15;80(2):422-7. doi: 10.1016/j.talanta.2009.03.019. Epub 2009 Mar 19.
7
Laser-based sensor for detection of hazardous gases in the air using waveguide CO2 laser.基于激光的传感器,用于使用波导二氧化碳激光检测空气中的有害气体。
J Environ Sci Health A Tox Hazard Subst Environ Eng. 2007 Jun;42(7):871-8. doi: 10.1080/10934520701372986.
8
Resonant Cell-Based 1 Photoacoustic Gas Analyzer Immune to Light Power Fluctuation and Frequency Mismatch.基于共振细胞的1光声气体分析仪,不受光功率波动和频率失配影响。
Anal Chem. 2024 Oct 22;96(42):16543-16550. doi: 10.1021/acs.analchem.4c01527. Epub 2024 Oct 8.
9
[Researches on the effect of gas humidity on photoacoustic spectroscopy gas detection system].[气体湿度对光声光谱气体检测系统影响的研究]
Guang Pu Xue Yu Guang Pu Fen Xi. 2011 Jul;31(7):1819-22.
10
[Remote system of natural gas leakage based on multi-wavelength characteristics spectrum analysis].基于多波长特征光谱分析的天然气泄漏远程检测系统
Guang Pu Xue Yu Guang Pu Fen Xi. 2014 May;34(5):1249-52.