Mannuß Steffen, Schuff-Werner Peter, Dreißiger Katrin, Kohlschein Peter
From the Rostock University Medical Centre, Institute of Clinical Chemistry and Laboratory Medicine, Rostock, Germany.
Am J Clin Pathol. 2016 Jun;145(6):806-14. doi: 10.1093/ajcp/aqw066. Epub 2016 Jun 8.
There are conflicting reports on the reliable measurement of platelet count and mean platelet volume (MPV) using EDTA or citrate. The anticoagulant properties of magnesium sulfate (MgSO4) are known from the literature. The aim of this study was to evaluate MgSO4 as an in vitro anticoagulant for platelet count, MPV, platelet distribution width, and platelet activation.
Whole blood from volunteers was anticoagulated by EDTA, citrate, or MgSO4 Platelets were counted by the XE 5000 (Sysmex, Norderstedt, Germany) impedance and fluorescence optical technique.
The mean impedance platelet counts were 227.7, 197.0, and 201.1 × 10(9)/L in EDTA-, citrate-, or MgSO4-anticoagulated blood, respectively. The counts were 4.7% higher (EDTA) after 3 hours of storage but 4% lower in citrate-anticoagulated blood. The counts in magnesium samples remained stable. The MPV was 10.4 fL (EDTA), 9.5 fL (citrate), and 9.3 fL (MgSO4). EDTA samples showed cell swelling within the first 3 hours. This was lower in citrate and only marginal in magnesium samples. High activation of platelets was observed only in EDTA samples.
Magnesium anticoagulation might be advantageous for more reliable MPV measurements. Although platelet count is underestimated when the impedance method is used, the platelet count reveals similar results when measured by the fluorescent optical method.
关于使用乙二胺四乙酸(EDTA)或柠檬酸盐可靠测量血小板计数和平均血小板体积(MPV)的报道相互矛盾。硫酸镁(MgSO4)的抗凝特性在文献中已有记载。本研究的目的是评估MgSO4作为血小板计数、MPV、血小板分布宽度和血小板活化的体外抗凝剂。
志愿者的全血用EDTA、柠檬酸盐或MgSO4抗凝。通过XE 5000(德国诺德施泰特Sysmex公司)阻抗和荧光光学技术对血小板进行计数。
EDTA、柠檬酸盐或MgSO4抗凝血液中的平均阻抗血小板计数分别为227.7、197.0和201.1×10⁹/L。储存3小时后,EDTA抗凝血液中的计数高4.7%,但柠檬酸盐抗凝血液中的计数低4%。镁样本中的计数保持稳定。MPV分别为10.4 fL(EDTA)、9.5 fL(柠檬酸盐)和9.3 fL(MgSO4)。EDTA样本在最初3小时内出现细胞肿胀。柠檬酸盐样本中的肿胀程度较低,镁样本中仅轻微肿胀。仅在EDTA样本中观察到血小板的高活化。
镁抗凝可能有利于更可靠地测量MPV。虽然使用阻抗法时血小板计数被低估,但通过荧光光学法测量时血小板计数显示出相似的结果。