Soulard Michel, Ketatni Hela, Visseaux Claire, Croix Pascale, Cohen Patrick
Biogroup Hematology Laboratory, La Chocolaterie, 92300 Levallois Perret, France.
Division of Laboratory Medecine, Diagnostic Department, Geneva University Hospitals and Faculty of Medicine, 1205 Geneva, Switzerland.
J Clin Med. 2024 Sep 10;13(18):5350. doi: 10.3390/jcm13185350.
: In EDTA-induced pseudothrombopenia, citrate or MgSO are recommended for platelet counting. Pre-analytical conditions are poorly defined for tubes containing MgSO or citrate. In this study, we analyzed the impact of agitation of these tubes on platelet counts. K2EDTA, citrate, and MgSO tubes from 70 patients were gently agitated on a wheel rotating at 20 rpm. Platelets were analyzed on the Sysmex XN analyzer at different times, and the percentage of platelet deviation from T0 was assessed and compared with the desirable bias of the EFLM. : at 180 min in fluorescence, the relative variation of platelets after shaking is 1.17% for K2EDTA, -29.76% for citrate, and -33.18% for MgSO, while for unshaken MgSO platelets the variation is -1.3%. The reduction in platelet numbers when citrate or MgSO tubes are shaken is linked to the appearance of platelet clusters. : agitation of MgSO and especially citrate tubes led to a decrease in platelet counts due to the formation of platelet aggregates; on the other hand, platelet counts on EDTA are virtually stable. During transport, we recommend putting sodium citrate and MgSO tubes in an upright position and avoiding shaking them to avoid giving an erroneous platelet result.
在乙二胺四乙酸(EDTA)诱导的假性血小板减少症中,推荐使用枸橼酸盐或硫酸镁进行血小板计数。对于含有硫酸镁或枸橼酸盐的试管,分析前条件定义不明确。在本研究中,我们分析了这些试管振荡对血小板计数的影响。对70例患者的K2EDTA、枸橼酸盐和硫酸镁试管在以20转/分钟旋转的轮子上轻轻振荡。在不同时间使用Sysmex XN分析仪分析血小板,并评估血小板相对于T0的偏差百分比,并与欧洲临床实验室标准协会(EFLM)的理想偏差进行比较。在荧光下180分钟时,振荡后K2EDTA血小板的相对变化为1.17%,枸橼酸盐为-29.76%,硫酸镁为-33.18%,而未振荡的硫酸镁血小板变化为-1.3%。枸橼酸盐或硫酸镁试管振荡时血小板数量的减少与血小板聚集体的出现有关。硫酸镁尤其是枸橼酸盐试管的振荡由于血小板聚集体的形成导致血小板计数减少;另一方面,EDTA管上的血小板计数实际上是稳定的。在运输过程中,我们建议将枸橼酸钠和硫酸镁试管直立放置并避免振荡,以避免给出错误的血小板结果。