Suppr超能文献

试纸法检测的随机尿pH值不能准确反映电极法检测的24小时尿pH值。

Dipstick Spot urine pH does not accurately represent 24 hour urine PH measured by an electrode.

作者信息

Omar Mohamed, Sarkissian Carl, Jianbo Li, Calle Juan, Monga Manoj

机构信息

Glickman Urological & Kidney Institute - Cleveland Clinic Foundation, Cleveland, OH, USA.

出版信息

Int Braz J Urol. 2016 May-Jun;42(3):546-9. doi: 10.1590/S1677-5538.IBJU.2015.0071.

Abstract

OBJECTIVES

To determine whether spot urine pH measured by dipstick is an accurate representation of 24 hours urine pH measured by an electrode.

MATERIALS AND METHODS

We retrospectively reviewed urine pH results of patients who presented to the urology stone clinic. For each patient we recorded the most recente pH result measured by dipstick from a spot urine sample that preceded the result of a 24-hour urine pH measured by the use of a pH electrode. Patients were excluded if there was a change in medications or dietary recommendations or if the two samples were more than 4 months apart. A difference of more than 0.5 pH was considered na inaccurate result.

RESULTS

A total 600 patients were retrospectively reviewed for the pH results. The mean difference in pH between spot urine value and the 24 hours collection values was 0.52±0.45 pH. Higher pH was associated with lower accuracy (p<0.001). The accuracy of spot urine samples to predict 24-hour pH values of <5.5 was 68.9%, 68.2% for 5.5 to 6.5 and 35% for >6.5. Samples taken more than 75 days apart had only 49% the accuracy of more recent samples (p<0.002). The overall accuracy is lower than 80% (p<0.001). Influence of diurnal variation was not significant (p=0.588).

CONCLUSIONS

Spot urine pH by dipstick is not an accurate method for evaluation of the patients with urolithiasis. Patients with alkaline urine are more prone to error with reliance on spot urine pH.

摘要

目的

确定用试纸条检测的随机尿pH值能否准确反映用电极测量的24小时尿pH值。

材料与方法

我们回顾性分析了泌尿外科结石门诊患者的尿pH值结果。对于每位患者,我们记录了在使用pH电极测量24小时尿pH值之前,从随机尿样中用试纸条测得的最新pH值。如果患者的药物或饮食建议有变化,或者两个样本间隔超过4个月,则将其排除。pH差值超过0.5被认为是不准确的结果。

结果

共回顾性分析了600例患者的pH值结果。随机尿pH值与24小时收集值之间的平均pH差值为0.52±0.45。pH值越高,准确性越低(p<0.001)。随机尿样预测24小时pH值<5.5的准确率为68.9%,5.5至6.5为68.2%,>6.5为35%。间隔超过75天采集的样本的准确率仅为近期样本的49%(p<0.002)。总体准确率低于80%(p<0.001)。昼夜变化的影响不显著(p=0.588)。

结论

用试纸条检测随机尿pH值不是评估尿路结石患者的准确方法。碱性尿患者依靠随机尿pH值更容易出错。