Suppr超能文献

尿道内刺激能否抑制正常雌性大鼠的排尿反射?

Can intraurethral stimulation inhibit micturition reflex in normal female rats?

作者信息

Yu Tian, Liao Limin, Wyndaele Jean Jacques

机构信息

Department translational neurosciences, Laboratory Urology, University of Antwerp, Faculty GGW, Belgium.

Department of Urology, University Hopsital Antwerp, Antwerp, Belgium.

出版信息

Int Braz J Urol. 2016 May-Jun;42(3):608-13. doi: 10.1590/S1677-5538.IBJU.2015.0135.

Abstract

OBJECTIVE

The study was designed to determine the effect of low frequency (2.5Hz) intraurethral electrical stimulation on bladder capacity and maximum voiding pressures.

MATERIALS AND METHODS

The experiments were conducted in 15 virgin female Sprague-Dawley rats (220-250g). The animals were anesthetized by intraperitoneal injection of urethane (1.5g/kg). Animal care and experimental procedures were reviewed and approved by the Institutional Animal Care and Use Committee of Antwerp University (code: 2013-50). Unipolar square pulses of 0.06mA were used to stimulate urethra at frequency of 2.5Hz (0.2ms pulse width) in order to evaluate the ability of intraurethral stimulation to inhibit bladder contractions. Continuous stimulation and intermitente stimulation with 5sec ''on'' and 5sec ''off'' duty cycle were applied during repeated saline cystometrograms (CMGs). Maximum voiding pressures (MVP) and bladder capacity were investigated to determine the inhibitory effect on bladder contraction induced by intraurethral stimulation.

RESULTS

The continuous stimulation and intermittent stimulation significantly (p<0.05) decreased MVP and increased bladder capacity. There was no significant difference in MVP and bladder capacity between continuous and intermittent stimulation group.

CONCLUSIONS

The present results suggest that 2.5Hz continuous and intermittent intraurethral stimulation can inhibit micturition reflex, decrease MVP and increase bladder capacity. There was no significant difference in MVP and bladder capacity between continuous and intermittent stimulation group.

摘要

目的

本研究旨在确定低频(2.5Hz)尿道内电刺激对膀胱容量和最大排尿压力的影响。

材料与方法

实验在15只未交配的雌性Sprague-Dawley大鼠(220-250g)身上进行。通过腹腔注射氨基甲酸乙酯(1.5g/kg)对动物进行麻醉。动物护理和实验程序经安特卫普大学机构动物护理和使用委员会审查并批准(代码:2013-50)。使用0.06mA的单极方波脉冲以2.5Hz的频率(0.2ms脉冲宽度)刺激尿道,以评估尿道内刺激抑制膀胱收缩的能力。在重复的生理盐水膀胱测压(CMG)过程中,采用持续刺激和占空比为5秒“开”和5秒“关”的间歇刺激。研究最大排尿压力(MVP)和膀胱容量,以确定尿道内刺激对膀胱收缩的抑制作用。

结果

持续刺激和间歇刺激均显著(p<0.05)降低了MVP并增加了膀胱容量。持续刺激组和间歇刺激组之间的MVP和膀胱容量无显著差异。

结论

目前的结果表明,2.5Hz的持续和间歇尿道内刺激可抑制排尿反射,降低MVP并增加膀胱容量。持续刺激组和间歇刺激组之间的MVP和膀胱容量无显著差异。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5fae/4920582/7f3ce23e90dc/1677-5538-ibju-42-3-0608-gf01.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验