Suhling Marie-Charlot, Majdani Omid, Salcher Rolf, Leifholz Melanie, Büchner Andreas, Lesinski-Schiedat Anke, Lenarz Thomas
Department of Otolaryngology, Medical University of Hanover, Hanover, Germany.
Otol Neurotol. 2016 Sep;37(8):1006-15. doi: 10.1097/MAO.0000000000001110.
The aim of the study was to determine the degree of hearing preservation (HP) and its relation to electrode array length after cochlear implantation using different thin flexible electrode arrays (TFEA).
Retrospective analysis.
One hundred twenty adult patients with preoperative residual hearing received a cochlear implant with a TFEA: 46 received a TFEA20, 34 a TFEA24, and 40 a TFEA28 mm.
Pure-tone audiometry (125-1500 Hz) was performed preoperatively, at initial fitting, and at 3, 6, and 12 months postoperatively. Median hearing loss (HL) was determined for each of the three array groups. The pre- to postoperative pure-tone average difference was scaled into three groups (≤15 dB, >15 to ≤30 dB, >30 dB) for array group.
At initial fitting, median HL of 17.5 dB (TFEA20), 20 dB (TFEA24), and 24 dB (TFEA28) was observed. At 12 months, medial HL of 15 dB (TFEA20), 19.4 dB (TFEA24), and 32.5 dB (TFEA28) was observed. At initial fitting, a HL of ≤15 dB was achieved in 45.6% TFEA20 subjects, 29.4% TFEA24 subjects, and 15.0% TFEA28 subjects; compared with 48.8% TFEA20 subjects, 50.0% TFEA24 subjects, and 15.8% TFEA28 subjects at 12 months.
HP is possible in the majority of subjects who are implanted with a TFEA20, 24, or 28. Using shorter arrays led to greater HP and lower median HL.
本研究旨在确定使用不同的薄型柔性电极阵列(TFEA)进行人工耳蜗植入后听力保留(HP)的程度及其与电极阵列长度的关系。
回顾性分析。
120例术前有残余听力的成年患者接受了TFEA人工耳蜗植入:46例接受了20毫米TFEA,34例接受了24毫米TFEA,40例接受了28毫米TFEA。
术前、初次调试时以及术后3个月、6个月和12个月进行纯音听力测定(125 - 1500赫兹)。确定三个阵列组各自的中位数听力损失(HL)。将术前至术后的纯音平均差异分为三组(≤15分贝、>15至≤30分贝、>30分贝)用于阵列组。
初次调试时,观察到的中位数HL分别为17.5分贝(20毫米TFEA)、20分贝(24毫米TFEA)和24分贝(28毫米TFEA)。12个月时,观察到的中位数HL分别为15分贝(20毫米TFEA)、19.4分贝(24毫米TFEA)和32.5分贝(28毫米TFEA)。初次调试时,20毫米TFEA组45.6%的受试者、24毫米TFEA组29.4%的受试者和28毫米TFEA组15.0%的受试者实现了≤15分贝的HL;12个月时,相应比例分别为20毫米TFEA组48.8%、24毫米TFEA组50.0%和28毫米TFEA组15.8%。
大多数植入20毫米、24毫米或28毫米TFEA的受试者都有可能实现听力保留。使用较短的阵列可带来更大程度的听力保留和更低的中位数HL。