Hinkson Larry, Siedentopf Jan-Peter, Weichert Alexander, Henrich Wolfgang
Department of Obstetrics, Charité - Universitätsmedizin Berlin, Berlin 13353, Germany.
Department of Obstetrics, Charité - Universitätsmedizin Berlin, Berlin 13353, Germany.
Eur J Obstet Gynecol Reprod Biol. 2016 Aug;203:232-8. doi: 10.1016/j.ejogrb.2016.06.003. Epub 2016 Jun 20.
A cesarean section rate of up to 19.4% is reported worldwide. Surgical site infection occurs with rates of up to 13.5%. Plastic-sheath wound retractors show reduced rates of surgical site infections in abdominal surgery. There is limited evidence in women having cesarean sections. This study evaluates the use of the Alexis(®) O C-Section Retractor in the prevention of surgical site infection in patients undergoing their first planned cesarean section compared to the traditional Collins self-retaining metal retractor.
A single center, prospective, randomized, controlled, observational trial. The primary outcome is surgical site infection as defined by the Centers for Disease Control and Prevention. The secondary outcomes included intraoperative surgical parameters, postoperative pain scores and the short and long-term satisfaction with wound healing. From October 2013 to December 2015 at the Charité University Hospital, Berlin. 98 patients to the Alexis(®) O C-Section Retractor group and 100 to the traditional Collins self-retaining metal retractor group.
A statistically significant reduction in the rate of surgical site infections, when the Alexis(®) O C-Section Retractor was used for wound retraction compared to the traditional Collins metal self-retaining wound retractor, 1% vs. 8% (RR 7.84, 95% CI (2.45-70.71) p=0.035).
The use of plastic-sheath wound retractors compared to the traditional self-retaining metal retractor in low risk women, having the first cesarean section is associated with a significantly reduced risk of surgical site infection.
据报道,全球剖宫产率高达19.4%。手术部位感染发生率高达13.5%。塑料鞘伤口牵开器在腹部手术中可降低手术部位感染率。剖宫产女性的相关证据有限。本研究评估了与传统柯林斯自持金属牵开器相比,Alexis(®)剖宫产牵开器在预防首次计划剖宫产患者手术部位感染中的应用。
一项单中心、前瞻性、随机、对照观察性试验。主要结局是疾病控制与预防中心定义的手术部位感染。次要结局包括术中手术参数、术后疼痛评分以及伤口愈合的短期和长期满意度。2013年10月至2015年12月在柏林夏里特大学医院进行。98例患者进入Alexis(®)剖宫产牵开器组,100例进入传统柯林斯自持金属牵开器组。
与传统柯林斯金属自持伤口牵开器相比,使用Alexis(®)剖宫产牵开器进行伤口牵开时,手术部位感染率有统计学意义的降低,分别为1%和8%(相对危险度7.84,95%置信区间(2.45 - 70.71),p = 0.035)。
在首次剖宫产的低风险女性中,与传统自持金属牵开器相比,使用塑料鞘伤口牵开器可显著降低手术部位感染风险。