Suppr超能文献

睫状肌麻痹对近视和远视儿童自动验光仪测量准确性的影响。

Cycloplegic influence on the accuracy of autorefractometer in myopic and hyperopic children.

作者信息

Prabhakar S K, Prathibha K S, Angadhi Pooja A, Singhal Anuj Kumar, Ara Raghavender Reddy, Naaz A Shamsiya

出版信息

Nepal J Ophthalmol. 2015 Jul;7(14):148-58. doi: 10.3126/nepjoph.v7i2.14965.

Abstract

OBJECTIVE

To investigate the cycloplegic effect on the accuracy of TOPCON AR RM-8000B autorefractometer in children.

MATERIALS AND METHODS

This study included 219 children of age 3 to 16 years. Topical 1% cyclopentolate hydrochloride was instilled for attaining cycloplegia. The children with the refractive error of -0.75 Diopter or more were grouped as myopic and more than +1.00 Diopter as hyperopic. Autorefraction was performed in addition to manual refraction. We used the XLSTAT and Medcalc statistics software.

RESULTS

Out of 219 children, 149 (68%) were emmetropic, 48 (22%) hyperopic and 22 (10%) myopic (n=70). Males and females constituted 29 (60.42%) and 19 (39.58%) respectively in hyperopic group where as 11 (54.55%) and 9 (45.45%) children were myopic. The means of ages of the children were 10.29 (+/- 2.96) and 13.14 (+/- 2.36) years in hyperopic and myopic groups respectively. Cycloplegic hyperopic and myopic autorefraction revealed mean sphere of +1.45 and -4.06 diopter with correlation coefficient of 0.95 and 0.99 respectively. Non-cycloplegic hyperopic autorefraction showed 74.2% sensitivity and 8.3% specificity at >-1 diopter with area under curve of 0.517 (p LESS THAN 0.0001). Cycloplegic hyperopic autorefraction showed 100% sensitivity and 97.1% specificity at >+1.85 diopter with accuracy of 0.616. Non-cycloplegic myopic autorefraction showed 100% sensitivity and 0.91% specificity at >-0.75 diopter with accuracy of 0.889. Cycloplegic myopic autorefraction showed 100% sensitivity and specificity at >-1.25 diopter with perfect accuracy.

CONCLUSION

Non-cycloplegic hyperopic autorefraction failed to identify true negative cases. Cycloplegic autorefraction identified true positive cases and myopic autorefraction was relatively unaffected by cycloplegia.

摘要

目的

研究睫状肌麻痹对TOPCON AR RM - 8000B自动验光仪测量儿童视力准确性的影响。

材料与方法

本研究纳入219名3至16岁儿童。局部滴注1%盐酸环喷托酯以实现睫状肌麻痹。屈光不正度数在-0.75屈光度及以上的儿童被归为近视组,屈光不正度数在+1.00屈光度及以上的儿童被归为远视组。除了进行人工验光外,还进行了自动验光。我们使用了XLSTAT和Medcalc统计软件。

结果

在219名儿童中,149名(68%)为正视眼,48名(22%)为远视眼,22名(10%)为近视眼(n = 70)。远视组中男性和女性分别占29名(60.42%)和19名(39.58%),近视组中分别有11名(54.55%)和9名(45.45%)儿童。远视组和近视组儿童的平均年龄分别为10.29(±2.96)岁和13.14(±2.36)岁。睫状肌麻痹下远视和近视自动验光显示平均球镜度数分别为+1.45和-4.06屈光度,相关系数分别为0.95和0.99。非睫状肌麻痹下远视自动验光在>-1屈光度时敏感性为74.2%,特异性为8.3%,曲线下面积为0.517(p<0.0001)。睫状肌麻痹下远视自动验光在>+1.85屈光度时敏感性为100%,特异性为97.1%,准确性为0.616。非睫状肌麻痹下近视自动验光在>-0.75屈光度时敏感性为100%,特异性为0.91%,准确性为0.889。睫状肌麻痹下近视自动验光在>-1.25屈光度时敏感性和特异性均为100%,准确性完美。

结论

非睫状肌麻痹下远视自动验光无法识别真正的阴性病例。睫状肌麻痹下自动验光可识别真正的阳性病例,且近视自动验光相对不受睫状肌麻痹的影响。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验