Suppr超能文献

用于种植体支持的固定义齿的无环和金属环包埋系统制作铸件的尺寸精度:一项体外比较研究。

Dimensional Accuracy of Castings Fabricated with Ring-less and Metal Ring Investment Systems for Implant Supported Fixed Dental Prosthesis: An In-vitro Comparative Study.

作者信息

Shah Rakesh, Singh J P, Kumar Manjit, D'Souza Dsj

机构信息

Graded Specialist (Prosthodontics), 1 CDU, C/o 56 APO.

Commandant, CMDC, Command Dental Advisor (SC), Pune-40.

出版信息

Med J Armed Forces India. 2011 Jan;67(1):46-51. doi: 10.1016/S0377-1237(11)80012-2. Epub 2011 Jul 21.

Abstract

BACKGROUND

The ring-less investment system is in use for dental casting, although there was no adequate scientific data to support its use either for conventional fixed dental prosthesis or implant retained fixed dental prosthesis.

METHODS

An in-vitro study was undertaken to compare the vertical marginal accuracy of single full coverage metal restorations, between ring-less and metal ring investment techniques, using two different investment materials, for implant supported fixed dental prosthesis. Three groups were made of ten samples each. Group I consisted of metal ring with PCT® FlexVest (phosphate bonded investment material). Group II consisted of metal ring with Bellasun® investment material. Group III and the final group consisted of ring-less investment system and Bellasun® investment material. The wax patterns were prepared on a metal die, cast and finished. The cast restorations (samples) were again seated on the metal die and the accuracy of fit was evaluated by measuring the gap between the finish line on the die and the margins of the sample at four specific sites using a profile projector (Helios-350H, Microtecnica, LTF, Italy) having accuracy of 1µm.

RESULT

Mean marginal accuracy for Group-III was found to be the least (58.87 +17.87 µm) followed by Group-II (97.23 + 16.37 µm), and Group-I (109 + 7.55 µm). However, Group I showed the least variability among the readings (SD=7.55).

CONCLUSION

Ring-less system of casting can be recommended for use in fabricating implant supported fixed dental restorations.

摘要

背景

无圈包埋系统用于牙科铸造,尽管没有足够的科学数据支持其用于传统固定义齿或种植体支持的固定义齿。

方法

进行一项体外研究,使用两种不同的包埋材料,比较无圈和金属圈包埋技术用于种植体支持的固定义齿时,单个全冠金属修复体的垂直边缘精度。将样本分为三组,每组十个。第一组由使用PCT® FlexVest(磷酸盐粘结包埋材料)的金属圈组成。第二组由使用Bellasun®包埋材料的金属圈组成。第三组也是最后一组由无圈包埋系统和Bellasun®包埋材料组成。在金属代型上制作蜡型,进行铸造和修整。将铸造修复体(样本)再次就位在金属代型上,使用精度为1µm的轮廓投影仪(Helios-350H,Microtecnica,LTF,意大利)在四个特定部位测量代型上的肩台线与样本边缘之间的间隙,评估适合度精度。

结果

发现第三组的平均边缘精度最低(58.87 +17.87 µm),其次是第二组(97.23 + 16.37 µm)和第一组(109 + 7.55 µm)。然而,第一组读数的变异性最小(标准差=7.55)。

结论

铸造的无圈系统可推荐用于制作种植体支持的固定牙科修复体。

相似文献

7
Marginal Accuracy of Castings Produced with Different Investment Systems.不同熔模铸造系统所生产铸件的边缘精度。
Med J Armed Forces India. 2009 Apr;65(2):146-9. doi: 10.1016/S0377-1237(09)80129-9. Epub 2011 Jul 21.

文献AI研究员