Lear J L, Feyerabend A, Gregory C
Department of Radiology, University of Colorado Health Sciences Center, Denver 80262.
Radiology. 1989 Aug;172(2):431-6. doi: 10.1148/radiology.172.2.2748823.
Discordance between effective renal plasma flow (ERPF) measurements from radionuclide techniques that use single versus multiple plasma samples was investigated. In particular, the authors determined whether effects of variations in distribution volume (Vd) of iodine-131 iodohippurate on measurement of ERPF could be ignored, an assumption implicit in the single-sample technique. The influence of Vd on ERPF was found to be significant, a factor indicating an important and previously unappreciated source of error in the single-sample technique. Therefore, a new two-compartment, two-plasma-sample technique was developed on the basis of the observations that while variations in Vd occur from patient to patient, the relationship between intravascular and extravascular components of Vd and the rate of iodohippurate exchange between the components are stable throughout a wide range of physiologic and pathologic conditions. The new technique was applied in a series of 30 studies in 19 patients. Results were compared with those achieved with the reference, single-sample, and slope-intercept techniques. The new two-compartment, two-sample technique yielded estimates of ERPF that more closely agreed with the reference multiple-sample method than either the single-sample or slope-intercept techniques.
研究了使用单份血浆样本与多份血浆样本的放射性核素技术所测得的有效肾血浆流量(ERPF)之间的差异。具体而言,作者确定了碘-131 碘马尿酸分布容积(Vd)的变化对 ERPF 测量的影响是否可以忽略,这是单样本技术中隐含的一个假设。结果发现 Vd 对 ERPF 的影响很大,这一因素表明单样本技术中存在一个重要且以前未被认识到的误差来源。因此,基于以下观察结果开发了一种新的两室、两份血浆样本技术:虽然不同患者的 Vd 会有所变化,但 Vd 的血管内和血管外成分之间的关系以及成分之间碘马尿酸的交换速率在广泛的生理和病理条件下都是稳定的。该新技术应用于 19 名患者的 30 项研究中。将结果与参考技术、单样本技术和斜率截距技术所获得的结果进行了比较。新的两室、两份样本技术所得到的 ERPF 估计值比单样本技术或斜率截距技术更接近参考多样本方法。