Department of Biochemistry and Molecular Pharmacology, IRCCS - Istituto di Ricerche Farmacologiche Mario Negri, Milano, Italy.
Department of Neuroscience, IRCCS -Istituto di Ricerche Farmacologiche Mario Negri, Milano, Italy.
Drug Test Anal. 2017 Jun;9(6):870-879. doi: 10.1002/dta.2052. Epub 2016 Sep 21.
4,4'-DMAR is an analogue of the known psychostimulants 4-methylaminorex and aminorex. In the light of reports of deaths associated with its abuse, and the easy access from Internet vendors, the EU Council recently decided on control measures across member states. Here we describe a validated method for measuring plasma levels of cis-4,4'-DMAR, crucial for preclinical studies and analysis in human plasma. Chromatographic separation was done by gradient elution on a Kinetex C18 column with 0.1% formic acid in water and 0.1% formic acid in acetonitrile at 0.2 mL/min. Detection was by positive electrospray ionization (ESI+) in multiple reaction monitoring mode monitoring the quantifier transitions m/z 191.4 → m/z 148.3 for cis-4,4'-DMAR and m/z 259.3 → m/z 194.2 for carbamazepine (internal standard). Protein precipitation with 1% of formic acid in acetonitrile was used in cis-4,4'-DMAR extraction from plasma; recovery was high (>93%) with a negligible matrix effect. This method provides an accurate, precise, and sensitive method for cis-4,4'-DMAR quantification in human and rat plasma, following European Medicine Agency guidelines for bioanalytical method validation. Pharmacokinetic studies were conducted in rats. After an intravenous dose of 1 mg/kg, plasma levels declined rapidly (≥80% in 4 h), followed by a slow elimination phase (t of 5.14 ± 0.65 h). Absorption was rapid after intraperitoneal injection (t = 15 min) with a rapid decline thereafter; C and AUC showed dose-proportionality over the dose range 1-10 mg/kg. This method was successfully applied to investigate pharmacokinetic properties in rats and could be used to quantify cis-4,4'-DMAR levels in human plasma. Copyright © 2016 John Wiley & Sons, Ltd.
4,4'-DMAR 是已知的苯丙胺类兴奋剂 4-甲基氨基苯丙醇和苯丙醇的类似物。鉴于其滥用导致死亡的报告,以及从互联网供应商那里很容易获得 4,4'-DMAR,欧盟委员会最近决定在成员国之间采取控制措施。在这里,我们描述了一种经过验证的方法,用于测量血浆中环式 4,4'-DMAR 的水平,这对于临床前研究和人血浆分析至关重要。色谱分离是通过在 Kinetex C18 柱上进行梯度洗脱实现的,流动相为 0.1%甲酸水溶液和 0.1%甲酸乙腈溶液,流速为 0.2 mL/min。检测采用正电喷雾电离(ESI+),在多重反应监测模式下,监测定量转化物的质荷比 m/z 191.4→m/z 148.3 用于 cis-4,4'-DMAR 和 m/z 259.3→m/z 194.2 用于卡马西平(内标)。在从血浆中提取 cis-4,4'-DMAR 时,使用 1%甲酸的乙腈进行蛋白质沉淀;回收率高(>93%),基质效应可忽略不计。该方法符合欧洲药品管理局生物分析方法验证指南,为 cis-4,4'-DMAR 在人血浆和大鼠血浆中的定量提供了一种准确、精确和灵敏的方法。在大鼠中进行了药代动力学研究。静脉注射 1mg/kg 后,血浆水平迅速下降(4 小时内下降≥80%),随后缓慢消除相(t 为 5.14±0.65 小时)。腹腔注射后吸收迅速(t 为 15 分钟),随后迅速下降;C 和 AUC 在 1-10mg/kg 的剂量范围内呈剂量比例关系。该方法成功应用于研究大鼠的药代动力学特性,并可用于定量人血浆中环式 4,4'-DMAR 的水平。版权所有©2016 年约翰威立父子公司