Early follow-up of patients with the Medtronic Intact porcine valve. A new cardiac bioprosthesis.

作者信息

Jaffe W M, Barratt-Boyes B G, Sadri A, Gavin J B, Coverdale H A, Neutze J M

机构信息

Department of Cardiology, Green Lane Hospital, Auckland, New Zealand.

出版信息

J Thorac Cardiovasc Surg. 1989 Aug;98(2):181-92.

PMID:2755151
Abstract

A new-generation porcine valve fixed in glutaraldehyde at zero pressure and mounted on an acetal copolymer flexible stent was inserted in 97 patients between August 1983 and October 1986. The mean age of the patients was 51 years (range 10 to 76) and eight were under the age of 20 years. There were 57 mitral, 33 aortic, and 10 tricuspid valve replacements. Concomitant coronary artery bypass grafting was performed in 9% of patients, 40% underwent multiple valve operations, and in 40% the procedure was a reoperation. Mean follow-up was 26 months (range 12 to 49) and was 99% complete. There were no examples of primary tissue failure, and only to reoperations have been undertaken for infective endocarditis alone. The early mortality rate was 8.2% and the late mortality rate, 12.1%. Four late deaths were valve related (two caused by infective endocarditis and two by embolism). The actuarial 3-year survival rate was 70%, freedom from infective endocarditis 879%, freedom from embolism 87%, freedom from reoperation 90%, and freedom from valve-related complications 77%. All but three surviving patients were in New York Heart Association class I or II. Doppler echocardiography, performed in 62 of 76 survivors, showed thin and mobile leaflets in all patients and trivial or mild regurgitation in four (6%). The mean gradient across the Medtronic Intact valves (Medtronic Blood Systems Inc., Minneapolis, Minn.) in the aortic position was 17 +/- 5.2 mm Hg, in the mitral position 3.8 +/- 1.33 mm Hg, and in the tricuspid position 4.1 +/- 1.14 mm Hg. We conclude that early results with the Intact valve are encouraging.

摘要

相似文献

1
Early follow-up of patients with the Medtronic Intact porcine valve. A new cardiac bioprosthesis.
J Thorac Cardiovasc Surg. 1989 Aug;98(2):181-92.
2
The zero pressure fixed medtronic intact porcine valve: an 8.5 year review.零压力固定美敦力完整猪瓣膜:8.5年回顾
J Heart Valve Dis. 1993 Sep;2(5):604-11.
3
The Medtronic Intact porcine bioprosthesis: clinical performance to eight years.美敦力完整猪生物假体:至八年的临床性能
J Heart Valve Dis. 1994 Nov;3(6):634-40.
4
The homograft aortic valve: a 29-year, 99.3% follow up of 1,022 valve replacements.同种异体主动脉瓣:1022例瓣膜置换术长达29年、随访率99.3%的随访结果
J Heart Valve Dis. 2001 May;10(3):334-44; discussion 335.
5
More than ten years' follow-up of the Hancock porcine bioprosthesis in Japan.日本对汉考克猪生物瓣膜的十多年随访。
J Thorac Cardiovasc Surg. 1992 Jul;104(1):5-13.
6
Six-and-half years' experience with the St. Jude BioImplant porcine prosthesis.
J Heart Valve Dis. 1997 Mar;6(2):138-44.
7
Late results of heart valve replacement with the Hancock II bioprosthesis.汉考克二代生物瓣膜心脏瓣膜置换术的远期结果
J Thorac Cardiovasc Surg. 2001 Feb;121(2):268-77. doi: 10.1067/mtc.2001.112208.
8
Medtronic mosaic porcine bioprosthesis: investigational center experience to six years.美敦力镶嵌式猪生物假体:至六年的研究中心经验
J Heart Valve Dis. 2005 Jan;14(1):54-63.
9
Experience with low-dose aspirin as thromboprophylaxis for the Tissuemed porcine aortic bioprosthesis: a survey of five years' experience.低剂量阿司匹林用于Tissuemed猪主动脉生物假体血栓预防的经验:五年经验调查
J Heart Valve Dis. 1998 Sep;7(5):574-9.
10
Six-year follow-up of the Toronto stentless porcine valve.
Semin Thorac Cardiovasc Surg. 2001 Oct;13(4 Suppl 1):168-72.

引用本文的文献

1
Diagnostic evaluation of left-sided prosthetic heart valve dysfunction.左侧人工心脏瓣膜功能障碍的诊断评估。
Nat Rev Cardiol. 2011 May 17;8(8):466-78. doi: 10.1038/nrcardio.2011.71.