Suppr超能文献

超声估计双胎胎儿体重的性能。

Performance of ultrasound fetal weight estimation in twins.

作者信息

Dimassi Kaouther, Karoui Abir, Triki Amel, Gara Mohamed Faouzi

出版信息

Tunis Med. 2016 Mar;94(3):203-9.

Abstract

BACKGROUND

Ultrasonography is an essential tool in the management of twin pregnancies. Fetal weight estimation is useful to anticipate neonatal care in case of weight restriction or growth discordance.

AIMS

To assess the accuracy of estimated fetal weight (EFW) in twins and to assess the accuracy of sonographic examination to predict birth weight discordance (BWD) and small birth weight (SBW).    Methods : This was  a longitudinal prospective study over a period of one year. We have included 50 twin pregnancies with a first trimester ultrasound calculated term and specified chorionicity. An ultrasound EFW was scheduled for all patients within an interval of 4 days before delivery. We calculated the differences between EFW and BW in terms of absolute difference and percentage error. We studied the correlation and the agreement between EFW and BW. Finally we calculated the sensitivity, the specificity, PPV and NPV of ultrasound in the diagnosis of BWD and SBW.

RESULTS

Absolute differences between BWF and BW were similar for the two twins. The relative difference was 7.7% [0-32] for T1 and 8.2% [0-27] for T2. The margin of error was greater than 10% in 38% of the cases for T1 and in 34% of cases for T2. Furthermore, correlation coefficients R1 and R2 for T1 and T2 were close to 1; R 1 =0.87 and  R 2 = 0.89. Linear regression analysis allowed us to calculate the birth weight based on the estimated weight and this according to the following equations: For the first twin BW T1 = 0.846 * EFW 415,57+ T1 For the second twin BW T2 = 65.68 + 0.963 * EFW T2 in 34% of cases for T2. Chorionicity, presentation and gestational age did not affect the estimations. Ultrasonography in the diagnosis of SBW had a sensitivity of 90.32%, a specificity of 76.82%, a (PPV) of 80% and a (VPN) of 87%. The performance of ultrasound in the diagnosis of BWD varied according to the adopted threshold.

CONCLUSION

Ultrasound is an effective examination to estimate twins weight. Regarding prenatal diagnosis of birth weight discordance, the relevance of this examination increases with the adopted threshold.

摘要

背景

超声检查是双胎妊娠管理中的一项重要工具。胎儿体重估计有助于在体重受限或生长不一致的情况下预测新生儿护理需求。

目的

评估双胎妊娠中估计胎儿体重(EFW)的准确性,并评估超声检查预测出生体重差异(BWD)和低出生体重(SBW)的准确性。

方法

这是一项为期一年的纵向前瞻性研究。我们纳入了50例双胎妊娠,这些妊娠在孕早期通过超声计算预产期并确定绒毛膜性。所有患者在分娩前4天内安排了一次超声EFW检查。我们计算了EFW与出生体重(BW)之间的绝对差异和百分比误差。我们研究了EFW与BW之间的相关性和一致性。最后,我们计算了超声诊断BWD和SBW的敏感性、特异性、阳性预测值(PPV)和阴性预测值(NPV)。

结果

两个胎儿的BWF与BW之间的绝对差异相似。T1的相对差异为7.7%[0 - 32],T2的相对差异为8.2%[0 - 27]。T1有38%的病例误差幅度大于10%,T2有34%的病例误差幅度大于10%。此外,T1和T2的相关系数R1和R2接近1;R1 = 0.87,R2 = 0.89。线性回归分析使我们能够根据估计体重计算出生体重,具体如下列方程所示:对于第一个胎儿,BW T1 = 0.846 * EFW + 415.57 + T1;对于第二个胎儿,BW T2 = 65.68 + 0.963 * EFW。T2有34%的病例符合此方程。绒毛膜性、胎位和孕周不影响估计结果。超声诊断SBW的敏感性为90.32%,特异性为76.82%,阳性预测值为80%,阴性预测值为87%。超声诊断BWD的性能因采用的阈值而异。

结论

超声是估计双胎体重的有效检查方法。关于出生体重差异的产前诊断,该检查的相关性随采用的阈值增加而提高。