Suppr超能文献

不同多焦点人工晶状体植入眼激光原位角膜磨镶术残余误差的可预测性及矢量分析

Predictability and Vector Analysis of Laser In Situ Keratomileusis for Residual Errors in Eyes Implanted With Different Multifocal Intraocular Lenses.

作者信息

Santhiago Marcony R, Ventura Bruna V, Ghanem Ramon C, Kara-Junior Newton, Moraes Haroldo V, Ghanem Emir

机构信息

*Department of Ophthalmology, University of Sao Paulo, Sao Paulo, Brazil; †Department of Ophthalmology, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil; ‡Department of Ophthalmology, Altino Ventura Foundation, Recife, Brazil; §Department of Ophthalmology, HOPE Eye Hospital, Recife, Brazil; and ¶Department of Ophthalmology, Sadalla Amin Ghanem Eye Hospital, Joinville, Brazil.

出版信息

Cornea. 2016 Nov;35(11):1404-1409. doi: 10.1097/ICO.0000000000000985.

Abstract

PURPOSE

To investigate potential differences in predictability, efficacy, and safety of corneal excimer laser to correct residual myopia, hyperopia, and astigmatism in eyes previously implanted with multifocal intraocular lenses using distinct optical surfaces and platforms for multifocality.

METHODS

This prospective comparative study included 37 eyes submitted to laser in situ keratomileusis correction for residual errors after implantation of either an apodized diffractive-refractive (Restor) or a full-diffractive (Tecnis) multifocal intraocular lens. Data analysis included investigation of predictability, efficacy, and safety of excimer laser surgery to correct residual errors. A double-angle plot, using vector analysis, was also created to evaluate predictability of astigmatism correction.

RESULTS

At 6-month follow-up, statistical analyses revealed a significant improvement when comparing preoperative (0.51 ± 0.25 and 0.44 ± 0.18) and postoperative values (0.17 ± 0.10 and 0.09 ± 0.07) of uncorrected distance visual acuity (P < 0.0001 and <0.0001), preoperative (0.92 ± 0.61 and 1.02 ± 0.45) and postoperative values (0.33 ± 0.23 and 0.19 ± 0.17) of manifest refractive spherical equivalent (P = 0.0006 and <0.0001), and preoperative (-1.08 ± 0.70 and -0.65 ± 0.42) and postoperative values (-0.25 ± 0.28 and -0.14 ± 0.21) of astigmatism (P < 0.0001 and <0.0001) in eyes implanted with Restor and Tecnis, respectively. Vector analysis revealed a predictable correction of astigmatism in all groups. Ninety-two percent of total eyes achieved a manifest refractive spherical equivalent within ±0.5 of emmetropia.

CONCLUSIONS

Corneal excimer laser refractive surgery seems to be equally effective to correct different residual errors, including astigmatism, in eyes implanted with intraocular lenses with various platforms for multifocality.

摘要

目的

研究使用不同光学表面和多焦点平台的角膜准分子激光,在先前植入多焦点人工晶状体的眼中矫正残余近视、远视和散光时,在可预测性、有效性和安全性方面的潜在差异。

方法

这项前瞻性比较研究纳入了37只眼睛,这些眼睛在植入变迹衍射折射型(Restor)或全衍射型(Tecnis)多焦点人工晶状体后,接受了准分子原位角膜磨镶术以矫正残余误差。数据分析包括对准分子激光手术矫正残余误差的可预测性、有效性和安全性的研究。还创建了一个使用矢量分析的双角图,以评估散光矫正的可预测性。

结果

在6个月的随访中,统计分析显示,分别比较植入Restor和Tecnis人工晶状体的眼睛的术前(未矫正远视力分别为0.51±0.25和0.44±0.18)和术后值(0.17±0.10和0.09±0.07)、术前(明显屈光球镜等效值分别为0.92±0.61和1.02±0.45)和术后值(0.33±0.23和0.19±0.17)以及术前(散光分别为-1.08±0.70和-0.65±0.42)和术后值(-0.25±0.28和-0.14±0.21)时,有显著改善(P<0.0001和<0.0001、P = 0.0006和<0.0001、P<0.0001和<0.0001)。矢量分析显示所有组的散光矫正均可预测。92%的眼睛的明显屈光球镜等效值在正视眼的±0.5范围内。

结论

角膜准分子激光屈光手术在矫正植入了具有不同多焦点平台的人工晶状体的眼睛中的不同残余误差(包括散光)方面似乎同样有效。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验