Donati F, Di Giacomo G, D'Adamio S, Ziranu A, Careri S, Rosa Ma, Maccauro G
Division of Orthopedic and Traumatology, Catholic University of the Sacred Heart, Rome, Italy.
Division of Orthopedic and Traumatology, Messina University, Messina, Italy.
Biomed Res Int. 2016;2016:9079041. doi: 10.1155/2016/9079041. Epub 2016 Aug 23.
Silver coating has demonstrated good antimicrobial activity and low toxicity. Silver-coated megaprostheses have been introduced in oncological musculoskeletal surgery considering the high rate of infection. We conducted a retrospective analysis on 68 cases of primary or metastatic bone tumors, affecting the proximal femur, treated between 2005 and 2016 with wide margins resection and tumor implants reconstruction. All patients were treated by the same surgeon, with antibiotic prophylaxis according to a standard protocol. In 55.9% of patients silver-coated hip hemiarthroplasty was implanted; in the remaining 44.1% uncoated megaprostheses were implanted. Patients were reevaluated recording the complications and focusing the analysis on infective complications. The average follow-up was 46.5 months. No patient has shown any sign of local or general silver toxicity. A SEM analysis was conducted on the 3-silver-coated hip hemiarthroplasty explanted confirming a severe degradation with a small amount of residual silver on the coating surface. Silver-coated hip prostheses have a lower rate of early infection than traditional implants but showed a reduction of antimicrobial activity for silver coating wear. We recommend using silver-coated prosthesis as primary implants for limb salvage surgery, in primary or metastatic bone tumors affecting the proximal femur, considering the absence of signs of toxicity and the lower rate of early infection.
银涂层已显示出良好的抗菌活性和低毒性。考虑到感染率高,银涂层的大假体已被引入肿瘤性肌肉骨骼手术中。我们对2005年至2016年间接受广泛边缘切除和肿瘤植入物重建治疗的68例影响股骨近端的原发性或转移性骨肿瘤病例进行了回顾性分析。所有患者均由同一位外科医生治疗,并根据标准方案进行抗生素预防。55.9%的患者植入了银涂层髋关节半关节成形术;其余44.1%的患者植入了未涂层的大假体。对患者进行重新评估,记录并发症,并将分析重点放在感染性并发症上。平均随访时间为46.5个月。没有患者出现任何局部或全身银中毒的迹象。对3个取出的银涂层髋关节半关节成形术进行了扫描电子显微镜分析,证实涂层严重降解,涂层表面残留少量银。银涂层髋关节假体的早期感染率低于传统植入物,但由于银涂层磨损,抗菌活性降低。考虑到没有毒性迹象和较低的早期感染率,我们建议将银涂层假体作为影响股骨近端的原发性或转移性骨肿瘤保肢手术的首选植入物。