J Biomed Mater Res B Appl Biomater. 2017 Nov;105(8):2507-2515. doi: 10.1002/jbm.b.33793. Epub 2016 Sep 23.
Due to degradation and metal dissolution during articulation of metal joint replacements the chemical periprosthetic environment may change. The aim was to establish whether metal replacements cause the local changes in pH and elevated metal concentrations.
pH was measured on samples from 167 patients: native hip and knee osteoarthritic joints, joints with hip and knee replacements revised for aseptic or septic reasons. pH of synovial fluid and periprosthetic tissue was measured perioperatively using a microelectrode and pH indicator papers for removed metal components. Metal concentrations were measured in 21 samples using inductively coupled plasma mass spectrometry.
The mean pH value of synovial fluid at native osteoarthritic joints (n = 101) was 7.78 ± 0.38. The mean pH value of synovial fluid at revision aseptic operation (n = 58) was 7.60 ± 0.31, with statistically significant difference (p = 0.002) compared to native osteoarthritic joints. The mean pH value of synovial fluid at revision septic operation (n = 8) was 7.55 ± 0.25, with statistically significant difference (p = 0.038) compared to native osteoarthritic joints. Measurements in tissue and at stems were not reliable. In the majority of samples taken at revision increased levels of cobalt and chromium were measured.
A small but statistically significant difference was observed in the pH of synovial fluid between natural joints with degenerative diseases and joints treated with metal replacements. Based on the increased metal levels we expected the value of pH to be lower, but the influence of metal ions is counteracted by the buffering capacity of human body. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 2507-2515, 2017.
由于金属关节置换术中的降解和金属溶解,假体周围的化学环境可能会发生变化。目的是确定金属置换物是否会导致局部 pH 值变化和金属浓度升高。
对 167 例患者的样本进行 pH 值测量:原发性髋关节和膝关节骨关节炎关节、因无菌或感染原因翻修的髋关节和膝关节置换关节。使用微电极和 pH 指示剂试纸测量术中取自滑膜和假体周围组织的样本的 pH 值,并测量已取出的金属部件的 pH 值。使用电感耦合等离子体质谱法测量 21 个样本中的金属浓度。
101 例原发性骨关节炎关节滑膜的平均 pH 值为 7.78 ± 0.38。58 例无菌翻修手术滑膜的平均 pH 值为 7.60 ± 0.31,与原发性骨关节炎关节相比有统计学显著差异(p = 0.002)。8 例感染性翻修手术滑膜的平均 pH 值为 7.55 ± 0.25,与原发性骨关节炎关节相比有统计学显著差异(p = 0.038)。组织和柄部的测量结果不可靠。在大多数翻修手术中,测量到钴和铬的水平升高。
在患有退行性疾病的自然关节和接受金属置换物治疗的关节的滑膜 pH 值之间观察到了小但有统计学意义的差异。基于金属水平升高,我们预计 pH 值会更低,但金属离子的影响被人体的缓冲能力抵消。© 2016 Wiley Periodicals, Inc. J 生物材料 Res 部分 B: 应用生物材料,105B:2507-2515, 2017。