测量犬动脉导管未闭最小导管直径的替代方法。

Alternative methods for the measurement of the minimal ductal diameter of a patent ductus arteriosus in a dog.

作者信息

Sanders R A, Olivier N B

机构信息

Michigan State University College of Veterinary Medicine, East Lansing, MI 48824, USA.

Michigan State University College of Veterinary Medicine, East Lansing, MI 48824, USA.

出版信息

J Vet Cardiol. 2016 Dec;18(4):372-376. doi: 10.1016/j.jvc.2016.08.002. Epub 2016 Sep 21.

Abstract

A two and half-year-old, 24 kg, spayed female German Shepherd was presented for evaluation of a suspected patent ductus arteriosus (PDA). Transthoracic echocardiographic examination confirmed a left to right shunting PDA. Closure of the PDA was recommended, and the owners elected to have minimally invasive transcatheter closure of the PDA performed. Standard ductal angiography failed to provide adequate measurements of the minimal ductal diameter (MDD). Alternative methods of measuring the MDD using an angiography catheter and a balloon catheter were performed. The PDA was occluded using an Amplatz Canine Ductal Occluder without complication. Further evaluation of these techniques is needed to determine the accuracy, overall clinical efficacy, and safety of using alternative methods for the measurement of the MDD of a PDA.

摘要

一只2.5岁、体重24千克的绝育雌性德国牧羊犬因疑似动脉导管未闭(PDA)前来接受评估。经胸超声心动图检查证实为左向右分流的动脉导管未闭。建议闭合动脉导管未闭,主人选择进行微创经导管动脉导管未闭闭合术。标准导管血管造影未能提供最小导管直径(MDD)的足够测量值。使用血管造影导管和球囊导管进行了测量MDD的替代方法。使用Amplatz犬用导管封堵器封堵动脉导管未闭,无并发症。需要对这些技术进行进一步评估,以确定使用替代方法测量动脉导管未闭MDD的准确性、总体临床疗效和安全性。

相似文献

1
Alternative methods for the measurement of the minimal ductal diameter of a patent ductus arteriosus in a dog.
J Vet Cardiol. 2016 Dec;18(4):372-376. doi: 10.1016/j.jvc.2016.08.002. Epub 2016 Sep 21.
2
Patent ductus arteriosus occlusion in small dogs utilizing a low profile Amplatz® canine duct occluder prototype.
J Vet Cardiol. 2015 Sep;17(3):203-9. doi: 10.1016/j.jvc.2015.06.002. Epub 2015 Sep 9.
4
Transesophageal echocardiography guided patent ductus arteriosus occlusion with a duct occluder.
J Vet Intern Med. 2013 Nov-Dec;27(6):1463-70. doi: 10.1111/jvim.12201. Epub 2013 Oct 1.
6
Echocardiographic and angiographic comparison of ductal dimensions in dogs with patent ductus arteriosus.
J Vet Intern Med. 2007 Jan-Feb;21(1):68-75. doi: 10.1892/0891-6640(2007)21[68:eaacod]2.0.co;2.
7
Transthoracic echocardiographic measurement of patent ductus arteriosus in dogs.
J Vet Intern Med. 2007 Mar-Apr;21(2):251-7. doi: 10.1892/0891-6640(2007)21[251:temopd]2.0.co;2.
8
Anatomy, baseline characteristics, and procedural outcome of patent ductus arteriosus in German Shepherd dogs.
J Vet Intern Med. 2019 Mar;33(2):471-477. doi: 10.1111/jvim.15401. Epub 2018 Dec 17.
9
Minimally invasive per-catheter patent ductus arteriosus occlusion in dogs using a prototype duct occluder.
J Vet Intern Med. 2008 Jan-Feb;22(1):129-34. doi: 10.1111/j.1939-1676.2007.0009.x.
10
Low profile vascular plug for transarterial occlusion of patent ductus arteriosus in small dogs.
J Vet Intern Med. 2021 Jan;35(1):98-106. doi: 10.1111/jvim.15966. Epub 2020 Nov 26.

引用本文的文献

1
Anatomy, baseline characteristics, and procedural outcome of patent ductus arteriosus in German Shepherd dogs.
J Vet Intern Med. 2019 Mar;33(2):471-477. doi: 10.1111/jvim.15401. Epub 2018 Dec 17.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验