Suppr超能文献

用于评估和诊断急性跟腱断裂的实时跟腱超声汤普森(RAUT)检查

Realtime Achilles Ultrasound Thompson (RAUT) Test for the Evaluation and Diagnosis of Acute Achilles Tendon Ruptures.

作者信息

Griffin Matthew J, Olson Kirstina, Heckmann Nathanael, Charlton Timothy P

机构信息

1 Keck Hospital of the University of Southern California, Department of Orthopaedic Surgery, Los Angeles, CA, USA.

2 University of California, San Francisco Medical Center, Department of Orthopaedic Surgery, San Francisco, CA, USA.

出版信息

Foot Ankle Int. 2017 Jan;38(1):36-40. doi: 10.1177/1071100716669983. Epub 2016 Oct 1.

Abstract

BACKGROUND

Acute complete Achilles tendon ruptures are commonly missed injuries. We propose the Realtime Achilles Ultrasound Thompson (RAUT) test, a Thompson test under ultrasound visualization, to aid in the diagnosis of these injuries. We hypothesized that RAUT testing would provide improved diagnostic characteristics compared with static ultrasound.

METHODS

Twenty-two consecutive patients with operatively confirmed acute Achilles tendon ruptures were prospectively evaluated with RAUT testing and static ultrasonography. RAUT video recordings and static ultrasound images from both ruptured and uninjured sides were randomized and graded by a group of novice reviewers and a group of expert attendings. From these observations, sensitivity, specificity, positive predictive value, and negative predictive value for RAUT and static ultrasound were calculated. In addition, κ interobserver coefficients were computed. Forty-seven novice reviewers and 11 foot and ankle attendings made a total of 4136 and 528 observations, respectively.

RESULTS

For static ultrasound, sensitivity and specificity were 76.8% and 74.8% for the novice reviewers and 79.6% and 86.4% for the attendings, respectively. For RAUT testing, sensitivity and specificity were 87.2% and 81.1% for the novice group and 86.4% and 91.7% for the attending group, respectively. The κ coefficient was 0.62 and 0.27 for novice and attending RAUT reviewers, indicating substantial and fair agreement, respectively, but only 0.46 and 0.12 for static ultrasonography, representing moderate and slight agreement, respectively.

CONCLUSION

RAUT testing was a sensitive and specific test, providing a cost-effective adjunct to the clinical examination when diagnosing acute Achilles tendon ruptures. This test can be used by surgeons with minimal training in ultrasonography.

LEVEL OF EVIDENCE

Level II, diagnostic study.

摘要

背景

急性跟腱完全断裂常为漏诊损伤。我们提出实时跟腱超声汤普森(RAUT)试验,即在超声可视化下进行的汤普森试验,以辅助诊断这些损伤。我们假设与静态超声相比,RAUT试验将提供更好的诊断特征。

方法

对22例经手术证实的急性跟腱断裂患者进行前瞻性RAUT试验和静态超声检查评估。将来自患侧和未受伤侧的RAUT视频记录和静态超声图像随机分组,由一组新手审阅者和一组专家主治医生进行分级。根据这些观察结果,计算RAUT和静态超声的敏感性、特异性、阳性预测值和阴性预测值。此外,计算观察者间κ系数。47名新手审阅者和11名足踝科主治医生分别进行了4136次和528次观察。

结果

对于静态超声,新手审阅者的敏感性和特异性分别为76.8%和74.8%,主治医生分别为79.6%和86.4%。对于RAUT试验,新手组的敏感性和特异性分别为87.2%和81.1%,主治医生组分别为86.4%和91.7%。新手和主治医生RAUT审阅者的κ系数分别为0.62和0.27,分别表示一致性良好和中等,但静态超声检查的κ系数仅为0.46和0.12,分别表示一致性中等和较弱。

结论

RAUT试验是一种敏感且特异的检查,在诊断急性跟腱断裂时是临床检查的一种经济有效的辅助手段。该检查外科医生经最少的超声检查培训即可使用。

证据水平

二级,诊断性研究。