Longo S, Cappone C, Saracco P, Bianco R, Oddenino O, Seberich C, Valori A, Miniero R
Minerva Pediatr. 1989 Apr;41(4):183-7.
We consider the approach through the left external jugular vein v/s right external jugular vein (Heinbach-Ivey technique) for the placement of central venous catheters (Broviac Hickman type and others) in pediatric patients. Between January '84 and February '87, 65 central venous catheters were inserted using the Heinbach Ivey technique. In 24.6% of the cases we failed and had to place the catheter through the right internal jugular vein. Between March '87 and November '88, 72 catheters were inserted through the left external jugular vein, only 5 through the left internal jugular vein, with a failure rate of 6%. Our data show that a more favourable anatomy makes easier and quicker the correct placement of a central venous catheter through a left external jugular vein approach.
我们探讨了在儿科患者中通过左颈外静脉与右颈外静脉(海因巴赫 - 艾维技术)放置中心静脉导管(布罗维阿克·希克曼型及其他类型)的方法。在1984年1月至1987年2月期间,采用海因巴赫 - 艾维技术插入了65根中心静脉导管。在24.6%的病例中,我们失败了,不得不通过右颈内静脉放置导管。在1987年3月至1988年11月期间,通过左颈外静脉插入了72根导管,仅通过左颈内静脉插入了5根,失败率为6%。我们的数据表明,更有利的解剖结构使得通过左颈外静脉途径更轻松、更快速地正确放置中心静脉导管。