Suppr超能文献

[Digital thermo-coronary angiography--development and validation of the method in comparison with conventional cine-coronary angiography].

作者信息

Mohr F W, Grundfest W, Litvack F, Forrester J, Matloff J, Kirchhoff P G

机构信息

Klinik für Herz- und Gefässchirurgie der Universitätsklinik Bonn.

出版信息

Z Kardiol. 1989 Jul;78(7):441-52.

PMID:2773540
Abstract

We describe the technique-thermal coronary angiography (TCA)-for real-time assessment of coronary anatomy and flow. The goal of this study was to compare thermal coronary angiography to cine coronary angiography and to validate its value for detecting stenoses. We studied the exposed LAD both in beating and arrested hearts in 11 open-chest pigs by TCA and cine angiography. We used an AGA 782 Thermovision system combined with a TIC 8000 digital image processor providing coronary images with 0.1-0.2 mm spatial and 0.1 degrees C thermal resolution, and a CFR x-ray system. The coronary arteries were catheterized via the right carotid artery, using standard 5F catheters. The thermal camera was focused at a 1m-distance to the heart surface and the x-ray was angled to LAO position. We performed simultaneous thermal and cine angiography using Angiovist 370 at different temperatures (10-40 degrees C) and injection rates (1-2.5 ml/s). Different grades of stenoses were created by snares. Thermistor probe readings of the epimyocardium and the left atrial blood were performed to reference the thermal camera measurements. We obtained high resolution TCA images of both the coronaries and of the myocardial perfusion beds whenever there was greater than 4 degrees C difference between injectate and epicardial temperature. The TCA detection of stenoses as compared to cine angiography was 29/30 (96.6%) in arrested and 36/42 (85.7%) in beating hearts. Coronary occlusion produced immediate and dramatic perfusion defects as detected by TCA. TCAs were highly reproducible. Injection rate of 2 ml/s provided optimal thermal coronary images. Thermal angiograms of the LAD were sometimes affected by large crossing coronary veins, myocardial bridges, and excess of fat pretending nonexistent coronary stenosis. TCA is a highly sensitive and reproducible method as compared to standard coronary angiography and allows for detection of coronary stenoses. The image quality was best in arrested hearts.

摘要

相似文献

8
Comparison of digital and cine coronary arteriography.
Int J Card Imaging. 1990;5(2-3):105-18. doi: 10.1007/BF01833979.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验