Case Rep Surg. 2016;2016:2019212. doi: 10.1155/2016/2019212. Epub 2016 Sep 21.
The plug-and-patch technique is frequently used for the open repair of inguinal hernias; however, serious complications may arise on rare occasions. We present the case of a 69-year-old patient who presented with a colocutaneous fistula with the sigmoid colon 9 years after the repair of a left sliding inguinal hernia with the plug-and-patch technique. The patient underwent sigmoidectomy and excision of the fistulous track. He was discharged on postoperative day 5 and had an uneventful recovery. Although such complications are reported rarely, the surgeon must be aware of them when deciding upon the method of hernia repair.