Suppr超能文献

采用TACTYS假体进行近端指间关节置换术:至少随访2年后的初步结果。

Arthroplasty of the proximal interphalangeal joint with the TACTYS prosthesis: Preliminary results after a minimum follow-up of 2 years.

作者信息

Athlani L, Gaisne E, Bellemère P

机构信息

Institut de la Main Nantes Atlantique, 21, rue des Martyrs, 44100 Nantes, France.

Institut de la Main Nantes Atlantique, 21, rue des Martyrs, 44100 Nantes, France.

出版信息

Hand Surg Rehabil. 2016 Jun;35(3):168-178. doi: 10.1016/j.hansur.2015.12.013. Epub 2016 May 31.

Abstract

The TACTYS implant is a new anatomic gliding articular and modular prosthesis for the proximal interphalangeal (PIP) joint. We report preliminary results with a minimum follow-up of 2 years. Twenty-two patients with a mean age of 63 years were operated on at a single center by two senior hand surgeons. Indications were painful and stiff PIP joints. The joint damage was caused by osteoarthritis (18 cases), post-traumatic arthritis (3) and rheumatoid arthritis (1). All prostheses were implanted through a dorsal mid-line transtendinous approach. Postoperative active and passive range of motion in flexion and extension was performed immediately with a protective splint for 2weeks. All patients were evaluated (pain, range of motion, strength, function, X-rays) with a mean follow-up of 34months (range 24-50). Pain decreased from 6.5 preoperatively to 1.9 postoperatively on a VAS scale. Flexion-extension range of motion increased from 39° preoperatively to 58° postoperatively. Grip strength was 21kg preoperatively and 25kg postoperatively. Pinch strength was 3kg preoperatively and 5kg postoperatively. Functional QuickDASH and PRWE scores were significantly improved at the last follow-up. Four patients were reoperated on: dorsal tenoarthrolysis in 3 cases and volar osteophyte removal in 1 case. All implants were still in place at the last follow-up. On X-rays, there were no signs of implant migration or loosening. The modularity of the prosthesis seems to be this implant's greatest advantage. The TACTYS prosthesis is a reliable alternative to other conventional PIP implants.

摘要

TACTYS植入物是一种用于近端指间(PIP)关节的新型解剖型滑动关节模块化假体。我们报告了至少随访2年的初步结果。22例平均年龄为63岁的患者在单一中心由两名资深手外科医生进行了手术。手术指征为疼痛和僵硬的PIP关节。关节损伤由骨关节炎(18例)、创伤后关节炎(3例)和类风湿关节炎(1例)引起。所有假体均通过背侧中线经肌腱入路植入。术后立即使用保护性夹板进行屈伸活动度的主动和被动训练,持续2周。对所有患者进行了评估(疼痛、活动度、力量、功能、X线检查),平均随访34个月(范围24 - 50个月)。视觉模拟评分法(VAS)显示疼痛从术前的6.5降至术后的1.9。屈伸活动度从术前的39°增加到术后的58°。握力术前为21kg,术后为25kg。捏力术前为3kg,术后为5kg。在最后一次随访时,功能QuickDASH和PRWE评分显著改善。4例患者接受了再次手术:3例行背侧腱鞘松解术,1例行掌侧骨赘切除术。在最后一次随访时,所有植入物均在位。X线检查未发现植入物移位或松动迹象。假体的模块化似乎是该植入物最大的优势。TACTYS假体是其他传统PIP植入物的可靠替代品。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验