Cox R A, Crifasi J A, Dickey R E, Ketzler S C, Pshak G L
Memorial Medical Center, Department of Laboratory Medicine, Springfield, Illinois 62781.
J Anal Toxicol. 1989 Jul-Aug;13(4):224-8. doi: 10.1093/jat/13.4.224.
Basic drugs were routinely extracted from whole blood under alkaline conditions into n-butyl acetate. An aliquot of the n-butyl acetate was injected into a gas chromatograph equipped with a nitrogen-phosphorous detector and a wide-bore cross-linked 50% phenylmethyl silicone capillary column. Absolute and relative retention times were recorded for more than 100 extracted drug standards. Recovery from whole blood was determined for some of the more frequently encountered drugs. This one-step extraction proved to be reliable for general screening and has been used routinely in forensic and clinical toxicological analyses.
碱性条件下,将基本药物从全血中常规萃取至乙酸正丁酯中。取一份乙酸正丁酯注入配有氮磷检测器和宽口径交联50%苯基甲基硅氧烷毛细管柱的气相色谱仪中。记录100多种萃取药物标准品的绝对保留时间和相对保留时间。测定了一些较常遇到药物在全血中的回收率。这一步萃取法经证明对于一般筛查是可靠的,并且已常规用于法医和临床毒理学分析。