Suppr超能文献

双参数3T磁共振成像在未经活检的前列腺癌患者群体中的检测应用:前列腺影像报告和数据系统(PI-RADS)v2的进一步改进?

Biparametric 3T Magnetic Resonance Imaging for prostatic cancer detection in a biopsy-naïve patient population: a further improvement of PI-RADS v2?

作者信息

Stanzione Arnaldo, Imbriaco Massimo, Cocozza Sirio, Fusco Ferdinando, Rusconi Giovanni, Nappi Carmela, Mirone Vincenzo, Mangiapia Francesco, Brunetti Arturo, Ragozzino Alfonso, Longo Nicola

机构信息

Department of Advanced Biomedical Sciences, University "Federico II", Naples, Italy.

Department of Advanced Biomedical Sciences, University "Federico II", Naples, Italy.

出版信息

Eur J Radiol. 2016 Dec;85(12):2269-2274. doi: 10.1016/j.ejrad.2016.10.009. Epub 2016 Oct 14.

Abstract

OBJECTIVES

To prospectively determine the diagnostic accuracy of a biparametric 3T magnetic resonance imaging protocol (BP-MRI) for prostatic cancer detection, compared to a multiparametric MRI protocol (MP-MRI), in a biopsy naïve patient population.

METHODS

Eighty-two untreated patients (mean age 65±7.6years) with clinical suspicion of prostate cancer and/or altered prostate-specific antigen (PSA) levels underwent a MP-MRI, including T2-weighted imaging, diffusion-weighted imaging (with the correspondent apparent diffusion coefficient maps) and dynamic contrast enhanced sequence, followed by prostate biopsy. Two radiologists reviewed both the BP-MRI and the MP-MRI protocols to establish a radiological diagnosis. Receiver operating characteristics curves were obtained to determine the diagnostic performance of the two protocols.

RESULTS

The mean PSA level was 8.8±8.1ng/ml. A total of 34 prostatic tumors were identified, with a Gleason score that ranged from 3+3 to 5+4. Of these 34 tumors, 29 were located within the peripheral zone and 5 in the transitional zone. BP-MRI and MP-MRI showed a similar performance in terms of overall diagnostic accuracy, with an area under the curve of 0.91 and 0.93, respectively (p=n.s.).

CONCLUSIONS

BP-MRI prostate protocol is feasible for prostatic cancer detection compared to a standard MP-MRI protocol, requiring a shorter acquisition and interpretation time, with comparable diagnostic accuracy to the conventional protocol, without the administration of gadolinium-based contrast agent.

摘要

目的

在未经活检的患者群体中,前瞻性地确定双参数3T磁共振成像方案(BP-MRI)与多参数MRI方案(MP-MRI)相比用于前列腺癌检测的诊断准确性。

方法

82例未经治疗、临床怀疑患有前列腺癌和/或前列腺特异性抗原(PSA)水平异常的患者(平均年龄65±7.6岁)接受了MP-MRI检查,包括T2加权成像、扩散加权成像(及相应的表观扩散系数图)和动态对比增强序列,随后进行前列腺活检。两名放射科医生对BP-MRI和MP-MRI方案进行评估以确立放射学诊断。通过绘制受试者工作特征曲线来确定两种方案的诊断性能。

结果

平均PSA水平为8.8±8.1ng/ml。共识别出34个前列腺肿瘤,Gleason评分范围为3+3至5+4。在这34个肿瘤中,29个位于外周区,5个位于移行区。BP-MRI和MP-MRI在总体诊断准确性方面表现相似,曲线下面积分别为0.91和0.93(p值无统计学意义)。

结论

与标准MP-MRI方案相比,BP-MRI前列腺方案在检测前列腺癌方面是可行的,采集和解读时间更短,诊断准确性与传统方案相当,且无需使用钆基造影剂。