Suppr超能文献

使用Ovation装置治疗腹主动脉瘤后的脉搏波分析

Pulse Wave Analysis after Treatment of Abdominal Aortic Aneurysms with the Ovation Device.

作者信息

Georgakarakos Efstratios, Argyriou Christos, Georgiadis George S, Lazarides Miltos K

机构信息

Department of Vascular Surgery, "Democritus" University of Thrace, University Hospital of Alexandroupolis, Alexandroupolis, Greece.

Department of Vascular Surgery, "Democritus" University of Thrace, University Hospital of Alexandroupolis, Alexandroupolis, Greece.

出版信息

Ann Vasc Surg. 2017 Apr;40:146-153. doi: 10.1016/j.avsg.2016.07.080. Epub 2016 Nov 25.

Abstract

BACKGROUND

Ovation aortic stent-graft system is a new device for the endovascular treatment of Abdominal Aortic Aneurysms achieving fixation via a 35-mm long, rigid anchored suprarenal stent and sealing stent at the infrarenal level by a means of a polymer-filling pair of inflatable O-rings, which cause narrowing of flow lumen and regional stenosis. Thus, concerns have been raised regarding hemodynamic consequences associated with this new design. Our preliminary report showed no significant increase of aortic pulse wave velocity (aPWV) immediately after implantation of the ovation in 3 patients. We studied further the hemodynamic implications of the Ovation implantation in 6 patients for a follow-up of 6 months.

METHODS

A brachial cuff-based automatic oscillometric device (Mobil-O-Graph; IEM, Stolberg, Germany) was used to perform noninvasively pulse wave analysis and stiffness estimation. Measurements were held preoperatively in 6 patients treated for abdominal aortic aneurysm, at the end of the first postoperative week, first and sixth postoperative month. Changes in systolic and diastolic blood pressure (cSyst, cDiast), heart rate, aPWV, augmentation index (AI@75), augmentation pressure (AP), and in the amplitude ratio of the reflected-to-forward pressure waves (reflection magnitude, RM) were recorded and compared. Significant change in any parameter was examined via analysis of variance repeated measures.

RESULTS

The cSyst was 132 ± 19.6, 127 ± 17.63, 131.3 ± 19.96, and 129.83 ± 31.72 mm Hg (P = 0.81) and cDiast was 88 ± 10.58, 86.83 ± 11.72, 89.83 ± 16.01, and 98.5 ± 24.56 mm Hg (P = 0.40). The heart rate showed an increasing yet nonsignificant tendency (67 ± 10.60, 75.1 ± 8.63, 74.33 ± 8.89, and 70.66 ± 6.65 beats/min, 0.27). The aPWV remained constant (11.61 ± 1.88, 11.6 ± 1.74, 11.8 ± 2.08, and 11.85 ± 2.30 m/sec, P = 0.79). Similarly, RM (71.16 ± 9.94, 60.66 ± 11.79, 61.5 ± 14.47, and 64.5 ± 3.78), AI@75 (33.83 ± 12.25, 22.16 ± 7.93, 27.83 ± 11.23, and 19.5 ± 14.72), and AP (18.33 ± 10.36, 9.83 ± 4.91, 11.5 ± 9.22, and 12 ± 15.08 mm Hg) remained practically unaltered during the follow-up period (P value: 0.79, 0.25, 0.10, and 0.27), respectively.

CONCLUSIONS

The implantation of the Ovation stent graft does not cause increase in aortic stiffness or in pulse wave reflection in the mid-period. The rationale of investigating noninvasively the impact of aortic stent grafts on the mechanical properties and the hemodynamic parameters should be encouraged because such findings may contribute to further development of newer endograft designs.

摘要

背景

Ovation主动脉覆膜支架系统是一种用于腹主动脉瘤血管内治疗的新型装置,它通过一个35毫米长的刚性锚定肾上支架实现固定,并通过一对可膨胀的聚合物填充O形环在肾下水平密封支架,这会导致血流腔变窄和局部狭窄。因此,人们对这种新设计的血流动力学后果表示担忧。我们的初步报告显示,3例患者植入Ovation后,主动脉脉搏波速度(aPWV)没有立即显著增加。我们进一步研究了6例患者植入Ovation后的血流动力学影响,随访6个月。

方法

使用基于肱动脉袖带的自动示波装置(Mobil-O-Graph;IEM,德国斯托尔伯格)进行无创脉搏波分析和硬度估计。在6例接受腹主动脉瘤治疗的患者术前、术后第一周结束时、术后第一个月和第六个月进行测量。记录并比较收缩压和舒张压(cSyst、cDiast)、心率、aPWV、增强指数(AI@75)、增强压力(AP)以及反射波与前向压力波的幅度比(反射幅度,RM)的变化。通过重复测量方差分析检查任何参数的显著变化。

结果

cSyst分别为132±19.6、127±17.63、131.3±19.96和129.83±31.72 mmHg(P = 0.81),cDiast分别为88±10.58、86.83±11.72、89.83±16.01和98.5±24.56 mmHg(P = 0.40)。心率呈上升趋势但无显著意义(67±10.60、75.1±8.63、74.33±8.89和70.66±6.65次/分钟,P = 0.27)。aPWV保持不变(11.61±1.88、11.6±1.74、11.8±2.08和11.85±2.30 m/秒,P = 0.79)。同样,RM(71.16±9.94、60.66±11.79、61.5±14.47和64.5±3.78)、AI@75(33.