Suppr超能文献

基于扩散张量成像纤维追踪技术术前预测大型前庭神经鞘瘤患者面神经的位置和形态

Preoperative Prediction of Location and Shape of Facial Nerve in Patients with Large Vestibular Schwannomas Using Diffusion Tensor Imaging-Based Fiber Tracking.

作者信息

Zhang Yanyang, Mao Zhiqi, Wei Penghu, Jin Yazhou, Ma Lin, Zhang Jun, Yu Xinguang

机构信息

Department of Neurosurgery, People's Liberation Army General Hospital, Beijing, China.

Department of Radiology, People's Liberation Army General Hospital, Beijing, China.

出版信息

World Neurosurg. 2017 Mar;99:70-78. doi: 10.1016/j.wneu.2016.11.110. Epub 2016 Nov 30.

Abstract

OBJECTIVE

Preserving the facial nerve (FN) during surgery for large vestibular schwannomas (VSs) is challenging because of the unpredictable locations and morphologic changes in the FN. Diffusion tensor imaging-based fiber tracking (DTI-FT) has been proposed to preoperatively visualize the FN. This study was performed to evaluate the efficacy of DTI-FT for predicting FN location and shape in patients with large VSs.

METHODS

In this prospective study, imaging data from 30 consecutive patients with large VSs were obtained using 3-T magnetic resonance imaging. The DTI-FT results included the location of the reconstructed FN relative to the tumor, and maximal fractional anisotropy (MFA) threshold values for FN tracking were determined with iPlan software. Intraoperative findings including the location of FN relative to the tumor and shape were determined by microscopic observations and electrophysiologic monitoring. A correlation analysis was performed between the DTI-FT results and intraoperative findings.

RESULTS

Preoperative visualization of the FN using DTI-FT was successful in all 30 patients. The location of the cisternal segment of the FN in relation to the tumors predicted by DTI-FT was consistent with the intraoperative findings in 29 (96.7%) of the 30 patients. The area under the curve of MFA for differentiation between the compact and flat FN was 0.84 (95% confidence interval [CI]: 0.69-0.98) (P = 0.002).

CONCLUSIONS

DTI-FT with modified tracking settings was useful to preoperatively predict the location of FN in patients with large VSs. The MFA of FN demonstrated moderate diagnostic performance for distinguishing compact from flat FNs.

摘要

目的

在大型前庭神经鞘瘤(VS)手术中保留面神经(FN)具有挑战性,因为FN的位置和形态变化不可预测。基于扩散张量成像的纤维追踪(DTI-FT)已被用于术前可视化FN。本研究旨在评估DTI-FT在预测大型VS患者FN位置和形态方面的有效性。

方法

在这项前瞻性研究中,连续30例大型VS患者的成像数据通过3-T磁共振成像获得。DTI-FT结果包括重建的FN相对于肿瘤的位置,并且使用iPlan软件确定FN追踪的最大分数各向异性(MFA)阈值。术中发现包括FN相对于肿瘤的位置和形态通过显微镜观察和电生理监测确定。对DTI-FT结果和术中发现进行相关性分析。

结果

在所有30例患者中,使用DTI-FT对FN进行术前可视化均成功。DTI-FT预测的FN脑池段相对于肿瘤的位置与30例患者中29例(96.7%)的术中发现一致。用于区分紧密型和平坦型FN的MFA曲线下面积为0.84(95%置信区间[CI]:0.69 - 0.98)(P = 0.002)。

结论

具有改良追踪设置的DTI-FT有助于术前预测大型VS患者FN的位置。FN的MFA在区分紧密型和平坦型FN方面显示出中等的诊断性能。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验