文献检索文档翻译深度研究
Suppr Zotero 插件Zotero 插件
邀请有礼套餐&价格历史记录

新学期,新优惠

限时优惠:9月1日-9月22日

30天高级会员仅需29元

1天体验卡首发特惠仅需5.99元

了解详情
不再提醒
插件&应用
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
高级版
套餐订阅购买积分包
AI 工具
文献检索文档翻译深度研究
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2025

Implantation of Stereoelectroencephalography Electrodes: A Systematic Review.

作者信息

Cardinale Francesco, Casaceli Giuseppe, Raneri Fabio, Miller Jonathan, Lo Russo Giorgio

机构信息

*"Claudio Munari" Center for Epilepsy Surgery, Niguarda Hospital, Piazza Ospedale Maggiore 3, Milan, Italy; and †Department of Neurological Surgery, University Hospitals Case Medical Center, Cleveland, Ohio, U.S.A.

出版信息

J Clin Neurophysiol. 2016 Dec;33(6):490-502. doi: 10.1097/WNP.0000000000000249.


DOI:10.1097/WNP.0000000000000249
PMID:27918344
Abstract

BACKGROUND: Stereoelectroencephalography (SEEG) was developed by Talairach and Bancaud in Paris in the late 1950s. Subsequently, the Talairach methodology was adopted at a number of additional centers in Europe and Canada. Technical aspects remained essentially unchanged for the following 30 years. Only in the last two decades, because of advancements in image-guided surgery systems, robotics, and computer-aided planning, use of SEEG has become more widespread, and reports describing these new developments have been published. OBJECTIVES: This systematic review was designed to assess published reports of SEEG surgical techniques and safety profile. DATA SOURCES: An electronic search was performed of Medline, Embase, and Scopus databases. In addition, the content pages of several standard epilepsy surgery textbooks were searched. Full-text English studies describing SEEG surgical technique or pertinent epidemiological data were included. Conference abstracts, reviews, posters, editorials, comments, and letters were excluded. RESULTS: Three hundred fifty-nine of 2,903 potentially eligible studies published by 32 centers were reviewed. Thirty-one of these primarily discussed the surgical technique. Thirty-five major complications (including 4 fatalities) were reported among 4,000 patients (0.8%) implanted with 33,000 electrodes. LIMITATIONS: The number of SEEG patients is likely to be underestimated because only a few groups have exhaustively reported their experience. Moreover, it is possible that a number of teams performing SEEG have not published studies on the topic. CONCLUSIONS: Rigorous SEEG, thanks to its basic principles and updated technologies, is a safe and accurate method to define the epileptogenic zone by means of stereotactically implanted intracerebral electrodes.

摘要

相似文献

[1]
Implantation of Stereoelectroencephalography Electrodes: A Systematic Review.

J Clin Neurophysiol. 2016-12

[2]
Is SEEG safe? A systematic review and meta-analysis of stereo-electroencephalography-related complications.

Epilepsia. 2016-3

[3]
Accuracy of intracranial electrode placement for stereoencephalography: A systematic review and meta-analysis.

Epilepsia. 2017-6

[4]
Health professionals' experience of teamwork education in acute hospital settings: a systematic review of qualitative literature.

JBI Database System Rev Implement Rep. 2016-4

[5]
What is the value of routinely testing full blood count, electrolytes and urea, and pulmonary function tests before elective surgery in patients with no apparent clinical indication and in subgroups of patients with common comorbidities: a systematic review of the clinical and cost-effective literature.

Health Technol Assess. 2012-12

[6]
The measurement and monitoring of surgical adverse events.

Health Technol Assess. 2001

[7]
Systemic pharmacological treatments for chronic plaque psoriasis: a network meta-analysis.

Cochrane Database Syst Rev. 2020-1-9

[8]
Eliciting adverse effects data from participants in clinical trials.

Cochrane Database Syst Rev. 2018-1-16

[9]
Systemic pharmacological treatments for chronic plaque psoriasis: a network meta-analysis.

Cochrane Database Syst Rev. 2021-4-19

[10]
The clinical effectiveness and cost-effectiveness of technologies used to visualise the seizure focus in people with refractory epilepsy being considered for surgery: a systematic review and decision-analytical model.

Health Technol Assess. 2012

引用本文的文献

[1]
Tactile exploration and imagery elicit distinct neural dynamics in the parietal cortical network.

Front Neurosci. 2025-7-24

[2]
Influences of electrode density on intracranial seizure localisation: a single-blinded randomised crossover study.

EBioMedicine. 2025-3

[3]
Vasogenic oedema during stereoelectroencephalography: intracranial pattern and late-onset clinical repercussion.

J Neurol. 2024-9

[4]
Robot-assisted stereotactic electroencephalography using 3-dimensional intraoperative imaging and frameless registration tool.

Neurosurg Focus Video. 2024-7-1

[5]
The Value of SINO Robot and Angio Render Technology for Stereoelectroencephalography Electrode Implantation in Drug-Resistant Epilepsy.

J Neurol Surg A Cent Eur Neurosurg. 2024-7-3

[6]
Frame-based versus robot-assisted stereo-electro-encephalography for drug-resistant epilepsy.

Acta Neurochir (Wien). 2024-2-16

[7]
Safety, Accuracy, and Efficacy of Robot-Assisted Stereo Electroencephalography in Children of Different Ages.

Neurosurgery. 2024-2-1

[8]
Robotic-Assisted Stereoelectroencephalography: A Systematic Review and Meta-Analysis of Safety, Outcomes, and Precision in Refractory Epilepsy Patients.

Cureus. 2023-10-25

[9]
Frameless robot-assisted stereoelectroencephalography-guided radiofrequency: methodology, results, complications and stereotactic application accuracy in pediatric hypothalamic hamartomas.

Front Neurol. 2023-10-19

[10]
Stereo-EEG tailored resection in a child with presumed perinatal post-stroke epilepsy: The complex organization of epileptogenic zone.

Epilepsy Behav Rep. 2023-8-5

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

推荐工具

医学文档翻译智能文献检索