Thien Ady, Rao Jai Prashanth, Ng Wai Hoe, King Nicolas Kon Kam
Department of Neurosurgery, National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore, 308433, Singapore.
Acta Neurochir (Wien). 2017 Feb;159(2):371-375. doi: 10.1007/s00701-016-3041-8. Epub 2016 Dec 10.
The use of fluorescein fluorescence-guided stereotactic needle biopsy has been shown to improve diagnostic accuracy and to expedite operative procedure in the stereotactic needle biopsy of high-grade gliomas. We developed a device (Fluoropen) for detecting fluorescence in brain tumor tissues obtained by fluorescein fluorescence-guided stereotactic needle biopsy.
The Fluoropen is a device consisting of a light source fitted with color filters to create the required emission and visualization wavelengths. The proof-of-concept study consisted of four consecutive patients who underwent fluorescein fluorescence-guided frameless stereotactic biopsy of brain tumor. Each sample was examined for the presence of fluorescence using the Fluoropen and compared with a microscope with fluorescence visualization capability.
A total of six samples were obtained from four stereotactic needle biopsy procedures. Four out of five samples (80%) taken from the contrast-enhancing part of the tumors were shown to be fluorescent under the microscope fitted with fluorescence module and the Fluoropen. One non-contrast enhancing lesion was non-fluorescent using both the microscope fitted with fluorescence module and the Fluoropen. The Fluoropen was shown to have 100% concordance with the microscope fitted with fluorescence module.
The Fluoropen is a low-cost and simple standalone device for the detection of fluorescein fluorescence that can expedite stereotactic needle biopsy by providing instant confirmation of the diagnostic sample and therefore avoid the need for an intraoperative frozen section. In patients with non-contrast enhancing tumors and those who were pre-treated with dexamethasone prior to surgery, fluorescein fluorescence-guided stereotactic needle biopsy will need to be used with caution.
荧光素荧光引导下的立体定向针吸活检已被证明可提高高级别胶质瘤立体定向针吸活检的诊断准确性并加快手术进程。我们开发了一种设备(荧光笔),用于检测通过荧光素荧光引导下的立体定向针吸活检获得的脑肿瘤组织中的荧光。
荧光笔是一种由配备滤色器的光源组成的设备,以产生所需的发射和可视化波长。概念验证研究包括连续4例接受荧光素荧光引导下脑肿瘤无框架立体定向活检的患者。使用荧光笔对每个样本进行荧光检测,并与具有荧光可视化功能的显微镜进行比较。
从4次立体定向针吸活检手术中总共获得了6个样本。在配备荧光模块的显微镜和荧光笔检测下,从肿瘤强化部分获取的5个样本中有4个(80%)显示为荧光阳性。一个非强化病变在配备荧光模块的显微镜和荧光笔检测下均无荧光。荧光笔与配备荧光模块的显微镜检测结果100%一致。
荧光笔是一种低成本、简单的独立设备,用于检测荧光素荧光,通过即时确认诊断样本可加快立体定向针吸活检,从而避免术中冰冻切片的需要。对于非强化肿瘤患者以及术前接受地塞米松预处理的患者,荧光素荧光引导下的立体定向针吸活检需谨慎使用。