Hydrophobic subtraction model (HSM) is widely applied to select columns of equivalent or different selectivity compared with a reference column, but its application in identifying optimal columns for specific separations of real samples is rare. In this work, a column selection method was proposed by firstly directly correlating separation selectivity of different pairs of solutes to column parameters based on the quantitative relationship of HSM and then selecting the optimal columns according to the predicted selectivity in consideration of the total separation of all critical pairs of solutes. Three critical pairs of solutes in clarithromycin impurity analysis were evaluated as examples. Starting with the analysis of clarithromycin impurities on 15 columns with different selectivities, ten optimal columns were finally identified for clarithromycin impurity analysis from the HSM column characterization database containing nearly 600 columns and two of them were validated with satisfactory separations for all critical peak pairs. The proposed methodology was also compared to the traditional column selection procedure based on calculations of scalar measures of the Euclidean distance between chromatographic columns. Results showed that our method provides an effective way to find the desired columns that may be overlooked by the traditional column selection due to selection of an inappropriate reference column or overestimation of column similarity, such as F introduced in HSM.

摘要

疏水减法模型(HSM)被广泛应用于选择与参比柱具有等效或不同选择性的色谱柱,但其在为实际样品的特定分离鉴定最佳色谱柱方面的应用却很少见。在本工作中,提出了一种色谱柱选择方法,首先基于HSM的定量关系将不同溶质对的分离选择性与色谱柱参数直接关联,然后根据预测的选择性并考虑所有关键溶质对的总分离情况来选择最佳色谱柱。以克拉霉素杂质分析中的三对关键溶质为例进行了评估。从对15根具有不同选择性的色谱柱上的克拉霉素杂质进行分析开始,最终从包含近600根色谱柱的HSM色谱柱表征数据库中确定了10根用于克拉霉素杂质分析的最佳色谱柱,其中两根对所有关键峰对的分离效果均得到验证且令人满意。还将所提出的方法与基于计算色谱柱之间欧几里得距离的标量度量的传统色谱柱选择程序进行了比较。结果表明,我们的方法提供了一种有效的途径来找到所需的色谱柱,而传统的色谱柱选择可能会因选择了不合适的参比柱或高估了色谱柱相似性(如HSM中引入的F)而忽略这些色谱柱。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验