Paty J, Macrez P, Renou A M, Brenot P, Gross C, Faure J M
Ann Anesthesiol Fr. 1978;19(3):191-9.
Recordings were electroencephalographical (EEG with spectral analysis), polygraphical (EMG, EKG, breathing). Visual and Auditory Cerebral Evoked Responses were also recorded. The depth of narcosis was quantified upon EEG data. The reactivity during the narcosis and the mechanisms of action of Etomidate on the "non specific structures" are discussed. Cautions should be taken with the use of tomidate in anesthesiology with epileptic and arteriopathic patients.
记录包括脑电图(EEG 及频谱分析)、多导记录(肌电图、心电图、呼吸)。还记录了视觉和听觉脑诱发电位。根据 EEG 数据对麻醉深度进行量化。讨论了麻醉期间的反应性以及依托咪酯对“非特异性结构”的作用机制。在麻醉学中,癫痫患者和动脉病患者使用依托咪酯时应谨慎。