The semiautomated kinetic procedure for determining cytoplasmic aspartate aminotransferase (c-AST) and mitochondrial aspartate aminotransferase (m-AST) activities was studied by the use of the immunoprecipitation method with anti-c-AST antibody in serum samples. The measured activity for m-AST remained constant after the addition of c-AST up to 1,000 IU/l throughout the 60-min incubation period. The measurements of m-AST activity were reproducible, selective and complete as determined by a purified m-AST. The precision of this method was as good as that of the manual method (CV 2.04%). The present method and the manual method gave approximately equal results for m-AST (r = 0.987). The effects of activations on m- and c-AST activity were compared by the addition of pyridoxal 5'-phosphate to sera of various diseases. A higher activation ratio by pyridoxal 5'-phosphate was observed on both aspartate aminotransferase activities in the serum of patients with ischemic heart diseases than in the serum of patients with liver diseases.

摘要

采用抗细胞质天冬氨酸氨基转移酶(c-AST)抗体免疫沉淀法,对血清样本中细胞质天冬氨酸氨基转移酶(c-AST)和线粒体天冬氨酸氨基转移酶(m-AST)活性的半自动动力学测定方法进行了研究。在整个60分钟的孵育期内,加入高达1000 IU/l的c-AST后,m-AST的测定活性保持恒定。通过纯化的m-AST测定,m-AST活性的测量具有可重复性、选择性和完整性。该方法的精密度与手工方法相当(变异系数为2.04%)。本方法和手工方法对m-AST的测定结果大致相同(r = 0.987)。通过向各种疾病患者的血清中添加5'-磷酸吡哆醛,比较了激活剂对m-AST和c-AST活性的影响。与肝病患者血清相比,缺血性心脏病患者血清中的两种天冬氨酸氨基转移酶活性均观察到更高的5'-磷酸吡哆醛激活率。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验