Suppr超能文献

使用新型眼前节扫频光学相干断层扫描技术测量下泪膜半月板及其与傅里叶域光学相干断层扫描技术的一致性

Lower Tear Meniscus Measurements Using a New Anterior Segment Swept-Source Optical Coherence Tomography and Agreement With Fourier-Domain Optical Coherence Tomography.

作者信息

Arriola-Villalobos Pedro, Fernández-Vigo José Ignacio, Díaz-Valle David, Almendral-Gómez Jaime, Fernández-Pérez Cristina, Benítez-Del-Castillo José M

机构信息

*Servicio de Oftalmología, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), Madrid, Spain; †Servicio de Oftalmología, Departamento de Oftalmología y ORL, Facultad de Medicina, Hospital Clínico San Carlos, Universidad Complutense de Madrid, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), Madrid, Spain; and ‡Unidad de Ayuda a la Investigación, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), Madrid, Spain.

出版信息

Cornea. 2017 Feb;36(2):183-188. doi: 10.1097/ICO.0000000000001086.

Abstract

PURPOSE

To assess intraobserver repeatability and interobserver and intersession reproducibility of lower tear meniscus height (LTMH) measurements obtained using a new anterior segment swept-source optical coherence tomography (SS-OCT) device. Agreement with Fourier-domain (FD) OCT (Spectralis) was also examined.

METHODS

In an observational cross-sectional study, one eye of 29 healthy subjects was randomly imaged with both devices at our center. Two examiners then randomly measured the LTMH using the software's calipers. To assess intraobserver repeatability and interobserver and intersession reproducibility, within-subject standard deviation (Sw), test-retest repeatability, coefficients of variation (CoV), and intraclass correlation coefficients (ICCs) were calculated. Agreement between both devices was also determined in Bland-Altman plots.

RESULTS

Mean LTMHs for SS-OCT and FD-OCT were 276.6 ± 87.6 and 280.3 ± 80 μm, respectively. Using the SS-OCT device, intraobserver CoV, interobserver CoV, and intersession CoV were found to be ≥16.9%, ≤7.2%, and ≤11.5%, respectively. ICCs for these parameters were ≤88%, ≥97%, and ≥94%, respectively. Bland-Altman analysis indicated poor agreement between SS-OCT and FD-OCT, and the correlation was low (CoV 34.5%, ICC 0.36).

CONCLUSIONS

SS-OCT LTMH measurements showed excellent interobserver and intersession repeatability along with good intraobserver reproducibility. Agreement between the devices was poor.

摘要

目的

评估使用新型眼前节扫频光学相干断层扫描(SS-OCT)设备测量下泪液半月皱襞高度(LTMH)时观察者内重复性、观察者间和不同检查间的可重复性。同时检查与傅里叶域(FD)OCT(Spectralis)的一致性。

方法

在一项观察性横断面研究中,29名健康受试者的一只眼睛在我们中心用这两种设备进行随机成像。然后两名检查者使用软件卡尺随机测量LTMH。为评估观察者内重复性、观察者间和不同检查间的可重复性,计算受试者内标准差(Sw)、重测重复性、变异系数(CoV)和组内相关系数(ICC)。还通过Bland-Altman图确定两种设备之间的一致性。

结果

SS-OCT和FD-OCT的平均LTMH分别为276.6±87.6和280.3±80μm。使用SS-OCT设备时,观察者内CoV、观察者间CoV和不同检查间CoV分别≥16.9%、≤7.2%和≤11.5%。这些参数的ICC分别≤88%、≥97%和≥94%。Bland-Altman分析表明SS-OCT和FD-OCT之间一致性较差,相关性较低(CoV 34.5%,ICC 0.36)。

结论

SS-OCT测量LTMH显示出优异的观察者间和不同检查间重复性以及良好的观察者内可重复性。两种设备之间的一致性较差。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验