Goracy E S
J Oral Surg. 1978 Nov;36(11):893-4.
A fracture of the body and ramus of the mandible occurred during a horizontal esteotomy for augmentation genioplasty. Care must be exercised when using osteotomes to free the posteroinferior border during this procedure.