Suppr超能文献

直立位应激时的主动脉波反射:体位和静脉淤积的影响

Aortic Wave Reflection During Orthostatic Challenges: Influence of Body Position and Venous Pooling.

作者信息

Hughes William E, Casey Darren P

机构信息

Department of Physical Therapy and Rehabilitation Science, Carver College of Medicine, University of Iowa, Iowa City, Iowa, USA.

出版信息

Am J Hypertens. 2017 Feb;30(2):166-172. doi: 10.1093/ajh/hpw138. Epub 2016 Nov 10.

Abstract

BACKGROUND

Aortic wave reflection (augmentation index; AIx) decreases during orthostatic challenges despite increased peripheral resistance, which is thought to be due to venous pooling. The purpose of this study was to examine if the decrease in AIx during an orthostatic challenge is due to venous pooling alone or body position manipulation.

METHODS

Twenty-three young, healthy adults (11F/12M) participated in 3 separate orthostatic challenges (5 minutes each); 60° head-up tilt (HUT), 60° HUT with bilateral rhythmic blood pressure (BP) cuff inflation on calves (75 mm Hg) to minimize venous pooling, and lower body negative pressure (LBNP; -30 mm Hg) for venous pooling independent of body position. High-fidelity radial artery pressure waveforms using applanation tonometry were recorded at minutes 2:30 and 5:00 during each condition. Aortic BP and wave reflection were analyzed from a synthesized aortic BP waveform.

RESULTS

Compared to resting (baseline) measurements, AIx did not significantly decrease at minutes 2:30 or 5:00 of HUT conditions (HUT 0 ± 2% vs. -3 ± 3%, 0 ± 2%; HUT w/cuffs 0 ± 2% vs. -4 ± 2%, 0 ± 2%). Conversely, LBNP substantially reduced AIx at minutes 2:30 and 5:00 (1 ± 2% vs. -15 ± 2% and -12 ± 2%; P < 0.01). When standardized to heart rate (AIx@75), AIx@75 increased relative to baseline during HUT conditions (P < 0.05).

CONCLUSIONS

In contrast to previous studies, AIx did not decrease during passive HUT, yet decreased substantially during LBNP. Despite being well matched for peripheral hemodynamics, it appears that LBNP elicits a greater effect on central hemodynamics, relative to passive HUT. Collectively, changes in body position alone do not explain differences in AIx during orthostatic conditions.

摘要

背景

尽管外周阻力增加,但在体位性应激期间主动脉波反射(增强指数;AIx)仍会降低,这被认为是由于静脉血液淤积所致。本研究的目的是探讨在体位性应激期间AIx的降低是否仅归因于静脉血液淤积或体位改变。

方法

23名年轻健康成年人(11名女性/12名男性)参与了3次独立的体位性应激试验(每次5分钟);60°头高位倾斜(HUT)、在小腿部进行双侧有节律的血压(BP)袖带充气(75 mmHg)以尽量减少静脉血液淤积的60°HUT,以及用于独立于体位的静脉血液淤积的下体负压(LBNP;-30 mmHg)。在每种情况下,于2分30秒和5分钟时使用压平式眼压计记录高保真桡动脉压力波形。从合成的主动脉血压波形分析主动脉血压和波反射。

结果

与静息(基线)测量相比,在HUT试验的2分30秒或5分钟时,AIx没有显著降低(HUT试验为0±2%对-3±3%,0±2%;带袖带的HUT试验为0±2%对-4±2%,0±2%)。相反,LBNP在2分30秒和5分钟时使AIx大幅降低(1±2%对-15±2%和-12±2%;P<0.01)。当以心率标准化时(AIx@75),在HUT试验期间AIx@75相对于基线增加(P<0.05)。

结论

与先前的研究相反,在被动HUT期间AIx没有降低,但在LBNP期间大幅降低。尽管外周血流动力学匹配良好,但相对于被动HUT,LBNP似乎对中心血流动力学产生更大的影响。总体而言,仅体位改变并不能解释体位性应激期间AIx的差异。