Suppr超能文献

液相色谱-串联质谱法测定人体血液和尿液中的硫代硫酸盐作为硫化氢中毒的指标

Liquid chromatography-tandem mass spectrometry method for the determination of thiosulfate in human blood and urine as an indicator of hydrogen sulfide poisoning.

作者信息

Maseda Chikatoshi, Hayakawa Akira, Okuda Katsuhiro, Asari Masaru, Tanaka Hiroki, Yamada Hiromi, Jin Shigeki, Horioka Kie, Matoba Kotaro, Shiono Hiroshi, Matsubara Kazuo, Shimizu Keiko

机构信息

Department of Legal Medicine, Asahikawa Medical University, 2-1-1-1 Midorigaoka-Higashi, Asahikawa 078-8510, Japan.

Tokyo Medical Examiner's Office, Tokyo Metropolitan Government, 4-21-18 Otsuka, Bunkyo-ku, Tokyo 112-0012, Japan.

出版信息

Leg Med (Tokyo). 2017 Jan;24:67-74. doi: 10.1016/j.legalmed.2016.12.004. Epub 2016 Dec 18.

Abstract

Being a stable metabolite of hydrogen sulfide, thiosulfate has been utilized as an index for hydrogen sulfide poisoning (HSP). Thiosulfate analysis is mainly performed using gas chromatography/mass spectrometry (GC-MS) due to its high sensitivity and specificity. The GC-MS analysis requires two-step derivatizations of thiosulfate, and the derivative is not stable in solution as it has a disulfide moiety. To resolve this stability issue, we developed a novel analytical method using liquid chromatography-tandem mass spectrometry (LC-MS/MS) for monitoring the pentafluorobenzyl derivative of thiosulfate (the first reaction product of the GC-MS method) in this study. The established method exhibited high reproducibility despite being a more simplified and rapid procedure compare to the GC-MS method. Phenyl 4-hydroxybenzoate was used as an internal standard because 1,3,5-tribromobenzene which had been used in the GC-MS method was not suitable compound for LC-MS/MS with Electrospray ionization (ESI) negative detection. The linear regression of the peak area ratios versus concentrations was fitted over the concentration ranges of 0.5-250μM and 0.25-250μM in blood and urine, respectively. The validation results satisfied the acceptance criteria for intra- and inter-day accuracy and precision. Blood and urine samples from 12 suspected HSP cases were tested using this method. The thiosulfate concentration detected in the sample coincided well with that determined at the scene of each HSP accident.

摘要

作为硫化氢的一种稳定代谢产物,硫代硫酸盐已被用作硫化氢中毒(HSP)的指标。由于其高灵敏度和特异性,硫代硫酸盐分析主要采用气相色谱/质谱联用(GC-MS)进行。GC-MS分析需要对硫代硫酸盐进行两步衍生化,且衍生物在溶液中不稳定,因为它含有二硫键部分。为了解决这个稳定性问题,我们在本研究中开发了一种使用液相色谱-串联质谱(LC-MS/MS)的新型分析方法,用于监测硫代硫酸盐的五氟苄基衍生物(GC-MS方法的第一个反应产物)。尽管与GC-MS方法相比,该方法更为简化和快速,但所建立的方法仍具有高重现性。使用对羟基苯甲酸苯酯作为内标,因为GC-MS方法中使用的1,3,5-三溴苯不适用于电喷雾电离(ESI)负离子检测的LC-MS/MS。峰面积比与浓度的线性回归分别在血液和尿液中0.5-250μM和0.25-250μM的浓度范围内拟合。验证结果满足日内和日间准确度和精密度的验收标准。使用该方法对12例疑似HSP病例的血液和尿液样本进行了检测。样本中检测到的硫代硫酸盐浓度与各HSP事故现场测定的浓度非常吻合。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验